7″ Ryder “GG” Needle Holder – 1mm jaws Left-Handed
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-38839
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-38839AISI 420 Martensitic

7″ Ryder GG Needle Holder 1mm Jaws Left-Handed

4.9 / 5.0•18 Verified OR Evaluations
$195.00$220.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $25.00 (11% OFF)
  • 7″ Ryder GG Needle Holder designed with a left-handed configuration for precise needle grasping.
  • 1mm jaw dimension provides a defined grasping profile for cardiovascular procedures.
  • Left-handed design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and microsurgery applications requiring a left-handed needle holder.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 7″ Ryder GG Needle Holder is a specialized cardiovascular instrument designed for precise manipulation of fine needles during microsurgical procedures. Its 1mm jaws provide a distinct working orientation that can assist with positioning the needle within the operative field.

With an overall length of 7 inches and 1mm jaw dimensions, this needle holder provides a defined grasping profile for vascular, ophthalmic, and delicate soft tissue applications. The left-handed configuration allows the working end to approach the surgical site from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 7-inch overall length for controlled manual handling.
  • 1mm jaw dimension provides a defined grasping profile.
  • Left-handed configuration for ergonomic comfort.
  • Designed for precise manipulation of fine needles.
  • Suitable for vascular, ophthalmic, and delicate soft tissue applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Ryder GG pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeRyder GG Needle Holder
Overall Length7″
Working End / Blade / Jaw1mm
ConfigurationLeft-Handed
Primary FunctionNeedle Grasping
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular / Microsurgery

The 7″ Ryder GG Needle Holder combines a 7-inch overall length with 1mm jaws and a left-handed configuration.
Its defined grasping profile is intended for precise manipulation of fine needles in cardiovascular applications.

Design & Function

The Ryder GG Needle Holder features a left-handed working configuration designed to provide a specialized orientation during microsurgical procedures. The 1mm jaw design can assist in positioning the needle according to the requirements of the operative field.

The 1mm jaw profile provides a defined grasping profile, while the 7-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a left-handed needle holder.

Surgical Applications

The 7″ Ryder GG Needle Holder may be used for cardiovascular and microsurgery applications involving precise needle manipulation. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the needle holder before use, paying particular attention to the jaws and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the needle holder appropriately to protect its jaws and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Needle Holder?
The overall length is 7 inches.

2. What is the working end / jaw design of the instrument?
It features 1mm jaws.

3. Is this Needle Holder left-handed or right-handed?
It features a left-handed configuration.

4. What is a Needle Holder used for?
It is designed for controlled needle grasping in cardiovascular applications.

5. What clinical advantage does the left-handed design provide?
The left-handed design provides a specialized working orientation for positioning the jaws within the operative field.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and microsurgery applications where a left-handed needle holder is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Needle Holder be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.