
8 1/2″ B-Clamp Straight Handle Angled Jaw
Direct Manufacturer Pricing • Tax Exclusive
- 8 1/2″ B-Clamp designed with a straight handle and angled jaws for controlled tissue clamping.
- Angled jaws provide a defined clamping profile for surgical procedures.
- Straight design supports a specialized working orientation within the operative field.
- Suitable for surgical and gynecologic applications requiring a B-Clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 8 1/2″ B-Clamp is a specialized surgical instrument designed for controlled tissue clamping in surgical and gynecologic procedures. Its angled jaws allow precise adaptation to tissue contours, providing secure and gentle clamping without excessive trauma.
With an overall length of 8 1/2 inches and a straight handle, this B-Clamp provides a defined clamping profile for surgical applications. The ergonomic design allows for direct force application while maintaining comfort for the surgeon during procedures.
Key Features
- 8 1/2-inch overall length for controlled manual handling.
- Straight handle with angled jaws provides a defined clamping profile.
- Angled jaw configuration for specialized working orientation.
- Designed for controlled tissue clamping.
- Suitable for surgical and gynecologic applications.
- Supports positioning of the working end within the operative field.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | B-Clamp |
| Overall Length | 8 1/2″ |
| Working End / Blade / Jaw | Angled jaws |
| Configuration | Straight |
| Primary Function | Tissue Clamping |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Surgical / Gynecologic |
The 8 1/2″ B-Clamp combines an 8 1/2-inch overall length with angled jaws and a straight handle.
Its defined working profile is intended for controlled tissue clamping in surgical and gynecologic applications.
Design & Function
The B-Clamp features a straight handle with angled jaws designed to provide a specialized orientation during tissue clamping. The angled jaw design can assist in positioning the working end according to the requirements of the operative field.
The angled jaws provide a defined clamping profile, while the 8 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for surgical procedures requiring a B-Clamp.
Surgical Applications
The 8 1/2″ B-Clamp may be used for surgical and gynecologic applications involving controlled tissue clamping. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the B-Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the B-Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this B-Clamp?
The overall length is 8 1/2 inches.
2. What is the working end / blade or tip design of the instrument?
It features angled jaws.
3. Is this B-Clamp curved or straight?
It features a straight configuration.
4. What is a B-Clamp used for?
It is designed for controlled tissue clamping in surgical applications.
5. What clinical advantage does the angled jaw provide?
The angled jaw provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for surgical procedures?
It may be used in surgical and gynecologic applications where a straight handle B-Clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the B-Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
