8 1/2″ Glover Spoon Clamp Atraumatic
Direct Manufacturer Pricing • Tax Exclusive
- 8 1/2″ Glover Spoon Clamp designed with an atraumatic configuration for vessel handling and occlusion.
- Spoon-shaped jaw design provides a defined clamping profile for cardiovascular procedures.
- Atraumatic design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and thoracic surgery applications requiring an atraumatic clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 8 1/2″ Glover Spoon Clamp is a specialized cardiovascular instrument designed for atraumatic handling and occlusion of large vessels during cardiovascular and thoracic procedures. Its spoon-shaped jaws distribute pressure evenly across the vessel, reducing trauma while maintaining secure control.
With an overall length of 8 1/2 inches and a spoon-shaped jaw design, this clamp provides a defined clamping profile for cardiovascular applications. The ergonomic design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 8 1/2-inch overall length for controlled manual handling.
- Spoon-shaped jaw design provides a defined clamping profile.
- Atraumatic configuration for specialized working orientation.
- Designed for atraumatic vessel handling and occlusion.
- Suitable for cardiovascular and thoracic surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Glover pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Glover Spoon Clamp |
| Overall Length | 8 1/2″ |
| Working End / Blade / Jaw | Spoon-shaped jaws |
| Configuration | Atraumatic |
| Primary Function | Vessel Handling and Occlusion |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Thoracic Surgery |
The 8 1/2″ Glover Spoon Clamp combines an 8 1/2-inch overall length with spoon-shaped jaws and atraumatic configuration.
Its defined working profile is intended for atraumatic vessel handling and occlusion in cardiovascular applications.
Design & Function
The Glover Spoon Clamp features an atraumatic working configuration designed to provide a specialized orientation during vessel occlusion. The spoon-shaped jaw design can assist in positioning the working end according to the requirements of the operative field.
The spoon-shaped jaw profile provides a defined clamping profile, while the 8 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring an atraumatic instrument type.
Surgical Applications
The 8 1/2″ Glover Spoon Clamp may be used for cardiovascular and thoracic surgery applications involving atraumatic vessel handling and occlusion. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Glover Spoon Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Glover Spoon Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Glover Spoon Clamp?
The overall length is 8 1/2 inches.
2. What is the working end / blade or tip design of the instrument?
It features spoon-shaped jaws.
3. Is this Glover Spoon Clamp curved or straight?
It features an atraumatic configuration.
4. What is a Glover Spoon Clamp used for?
It is designed for controlled vessel handling and occlusion in cardiovascular applications.
5. What clinical advantage does the spoon-shaped design provide?
The spoon-shaped design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and thoracic surgery applications where an atraumatic clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Glover Spoon Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.