8 1/4″ Panther Suction Retractor Extra Wide 6mm 16Fr
Direct Manufacturer Pricing • Tax Exclusive
- 8 1/4″ Panther Suction Retractor Extra Wide 6mm 16Fr designed with an extra wide configuration for controlled fluid aspiration and tissue retraction.
- 16 Fr suction size provides a defined suction profile for neurosurgical procedures.
- Extra wide design supports a specialized working orientation within the operative field.
- Suitable for neurosurgical and minimally invasive surgery applications requiring an extra wide suction retractor.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 8 1/4″ Panther Suction Retractor Extra Wide 6mm 16Fr is a specialized neurosurgical instrument designed for controlled fluid aspiration and tissue retraction. Its integrated lip provides a distinct working orientation that can assist with positioning the suction and retraction functions within the operative field.
With an overall length of 8 1/4 inches and a 16 Fr suction size, this suction retractor provides a defined working profile for neurosurgical applications. The extra wide 6 mm configuration allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 8 1/4-inch overall length for controlled manual handling.
- 16 Fr suction size provides a defined suction profile.
- Extra wide 6 mm configuration for specialized working orientation.
- Designed for controlled fluid aspiration and tissue retraction.
- Suitable for neurosurgical applications.
- Supports positioning of the working end within the operative field.
- Specialized Panther pattern for professional neurosurgical instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Panther Suction Retractor |
| Overall Length | 8 1/4″ |
| Working End / Blade / Jaw | 6 mm or Lip Design |
| Configuration | Extra Wide |
| Primary Function | Fluid Aspiration and Tissue Retraction |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Neurosurgical |
The 8 1/4″ Panther Suction Retractor Extra Wide 6mm 16Fr combines a 8 1/4-inch overall length with a 16 Fr suction size and extra wide 6 mm configuration.
Its defined working profile is intended for controlled fluid aspiration and tissue retraction in neurosurgical applications.
Design & Function
The Panther Suction Retractor features an extra wide working configuration designed to provide a specialized orientation during neurosurgical procedures. The lip design can assist in positioning the working end according to the requirements of the operative field.
The 6 mm working dimension provides a defined suction profile, while the 8 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring an extra wide suction retractor.
Surgical Applications
The 8 1/4″ Panther Suction Retractor Extra Wide 6mm 16Fr may be used for neurosurgical and minimally invasive surgery applications involving controlled fluid aspiration and tissue retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the suction retractor before use, paying particular attention to the working end, lip alignment, and suction profile. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the suction retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Suction Retractor?
The overall length is 8 1/4 inches.
2. What is the working end / blade or tip design of the instrument?
It features 6 mm working width or Lip design.
3. Is this Suction Retractor curved or straight?
It features an Extra Wide configuration.
4. What is a Suction Retractor used for?
It is designed for controlled fluid aspiration and tissue retraction in neurosurgical applications.
5. What clinical advantage does the lip design provide?
The lip provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and minimally invasive surgery applications where an extra wide suction retractor is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Suction Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.