8 1/4″ Diethrich Aorta Clamp 4.7cm Wide
Direct Manufacturer Pricing • Tax Exclusive
- 8 1/4″ Diethrich Aorta Clamp designed with a straight configuration for secure aortic occlusion.
- 4.7 cm jaw width provides a defined clamping profile for cardiovascular procedures.
- Straight design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and vascular surgery applications requiring a straight aorta clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 8 1/4″ Diethrich Aorta Clamp is a specialized cardiovascular instrument designed for secure and controlled occlusion of the aorta during cardiovascular and major vascular procedures. Its wide jaw provides a distinct working orientation that can assist with positioning the clamping end within the operative field.
With an overall length of 8 1/4 inches and a 4.7 cm jaw width, this clamp provides a defined clamping profile for cardiovascular applications. The deep design allows the working end to approach the anatomical target from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 8 1/4-inch overall length for controlled manual handling.
- 4.7 cm jaw width provides a defined clamping profile.
- 16 cm depth for accommodating large vascular structures.
- Designed for secure aortic occlusion.
- Suitable for cardiovascular and major vascular applications.
- Supports positioning of the working end within the operative field.
- Specialized Diethrich pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Diethrich Aorta Clamp |
| Overall Length | 8 1/4″ |
| Working End / Blade / Jaw | 4.7 cm Jaw Width |
| Configuration | Straight |
| Primary Function | Aortic Occlusion |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Vascular Surgery |
The 8 1/4″ Diethrich Aorta Clamp combines an 8 1/4-inch overall length with a 4.7 cm jaw width and a straight configuration.
Its defined working profile is intended for secure aortic occlusion in cardiovascular applications.
Design & Function
The Diethrich Aorta Clamp features a straight working configuration designed to provide a specialized orientation during aortic occlusion. The jaw design can assist in positioning the clamping end according to the requirements of the operative field.
The 4.7 cm jaw width provides a defined clamping profile, while the 8 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a straight instrument type.
Surgical Applications
The 8 1/4″ Diethrich Aorta Clamp may be used for cardiovascular and vascular surgery applications involving secure occlusion of the aorta. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Diethrich Aorta Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Diethrich Aorta Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Diethrich Aorta Clamp?
The overall length is 8 1/4 inches.
2. What is the working end / blade or tip design of the instrument?
It features 4.7 cm jaw width.
3. Is this Diethrich Aorta Clamp curved or straight?
It features a Straight configuration.
4. What is a Diethrich Aorta Clamp used for?
It is designed for controlled aortic occlusion in cardiovascular applications.
5. What clinical advantage does the straight design provide?
The straight design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular applications where a straight aorta clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Diethrich Aorta Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.