8″ Debakey Multi-Purpose Aorta Clamp 90° Angled
Direct Manufacturer Pricing • Tax Exclusive
- 8″ Debakey Multi-Purpose Aorta Clamp designed with a 90° angled configuration for secure aortic occlusion.
- Atraumatic Debakey teeth provide a defined clamping profile for cardiovascular procedures.
- Angled design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and thoracic applications requiring a multi-purpose clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 8″ Debakey Multi-Purpose Aorta Clamp is a specialized cardiovascular instrument designed for secure and atraumatic aortic occlusion. Its 90° angled design provides enhanced access in deep or restricted operative fields, allowing for effective positioning of the clamp within the surgical site.
With an overall length of 8 inches and a right-angle configuration, this aorta clamp provides a defined clamping profile for cardiovascular applications. The atraumatic Debakey teeth ensure firm vessel control without causing tissue damage, supporting controlled manual manipulation during procedures.
Key Features
- 8-inch overall length for optimal reach and handling.
- 90° angled design provides enhanced access in restricted fields.
- Atraumatic Debakey teeth for secure vessel control without tissue damage.
- Designed for secure aortic occlusion in cardiovascular procedures.
- Suitable for thoracic and cardiovascular applications.
- Supports positioning of the clamp within the operative field.
- Specialized Debakey pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Debakey Aorta Clamp |
| Overall Length | 8″ |
| Working End / Blade / Jaw | Atraumatic Debakey teeth |
| Configuration | Angled 90° |
| Primary Function | Aortic Occlusion |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Thoracic Surgery |
The 8″ Debakey Multi-Purpose Aorta Clamp combines an 8-inch overall length with atraumatic Debakey teeth and a 90° angled configuration.
Its defined clamping profile is intended for secure aortic occlusion in cardiovascular applications.
Design & Function
The Debakey Aorta Clamp features a 90° angled configuration designed to provide specialized orientation during cardiovascular procedures. The atraumatic teeth can assist in positioning the clamp according to the requirements of the operative field.
The atraumatic Debakey teeth provide a defined clamping profile, while the 8-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring an angled clamp.
Surgical Applications
The 8″ Debakey Multi-Purpose Aorta Clamp may be used for cardiovascular and thoracic surgery applications involving secure aortic occlusion. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Debakey Aorta Clamp before use, paying particular attention to the working end and jaw alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Debakey Aorta Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Aorta Clamp?
The overall length is 8 inches.
2. What is the working end / blade or tip design of the instrument?
It features atraumatic Debakey teeth.
3. Is this Aorta Clamp curved or straight?
It features a 90° angled configuration.
4. What is a Debakey Aorta Clamp used for?
It is designed for controlled aortic occlusion in cardiovascular applications.
5. What clinical advantage does the angled design provide?
The angled design provides a specialized working orientation for positioning the clamp within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and thoracic applications where a 90° angled clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Aorta Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.