8″ Kay Lamp Aorta Anastomosis Clamp 1.9cm Deep
Direct Manufacturer Pricing • Tax Exclusive
- 8″ Kay Lamp Aorta Anastomosis Clamp 1.9cm Deep designed with a deep configuration for precise vessel control during aortic anastomosis.
- 1.9 cm deep jaw provides a defined clamping profile for cardiovascular procedures.
- Ergonomic design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and aortic surgery applications requiring a deep jaw clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 8″ Kay Lamp Aorta Anastomosis Clamp 1.9cm Deep is a specialized cardiovascular instrument designed for precise and atraumatic vessel control during aortic anastomosis procedures. Its deep jaw design provides a distinct working orientation that can assist with positioning the vessel within the operative field.
With an overall length of 8 inches and a 1.9 cm deep jaw, this clamp provides a defined clamping profile for cardiovascular applications. The titanium construction allows the working end to approach the vessel from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 8-inch overall length for controlled manual handling.
- 1.9 cm deep jaw provides a defined clamping profile.
- Ergonomic design for specialized working orientation.
- Designed for precise vessel control during aortic anastomosis.
- Suitable for advanced cardiovascular surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Kay Lamp pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade titanium construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Kay Lamp Aorta Anastomosis Clamp |
| Overall Length | 8″ |
| Working End / Blade / Jaw | 1.9 cm deep jaw |
| Configuration | Deep |
| Primary Function | Vessel Control |
| Material | Titanium |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular Surgery |
The 8″ Kay Lamp Aorta Anastomosis Clamp 1.9cm Deep combines an 8-inch overall length with a 1.9 cm deep jaw and ergonomic design.
Its defined working profile is intended for precise vessel control in cardiovascular applications.
Design & Function
The Kay Lamp Aorta Anastomosis Clamp features a deep working configuration designed to provide a specialized orientation during aortic anastomosis. The deep jaw design can assist in positioning the vessel according to the requirements of the operative field.
The 1.9 cm deep jaw provides a defined clamping profile, while the 8-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a deep jaw clamp.
Surgical Applications
The 8″ Kay Lamp Aorta Anastomosis Clamp 1.9cm Deep may be used for cardiovascular and aortic surgery applications involving precise vessel control. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Kay Lamp Aorta Anastomosis Clamp before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Kay Lamp Aorta Anastomosis Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Clamp?
The overall length is 8 inches.
2. What is the working end / blade or tip design of the instrument?
It features 1.9 cm deep jaw.
3. Is this Clamp curved or straight?
It features a deep configuration.
4. What is a Clamp used for?
It is designed for controlled vessel control in cardiovascular applications.
5. What clinical advantage does the deep jaw design provide?
The deep jaw provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and aortic applications where a deep jaw clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.