9″ Babcock Tissue Forceps Atraumatic Design
Direct Manufacturer Pricing • Tax Exclusive
- 9″ Babcock Tissue Forceps designed with a straight configuration for atraumatic tissue grasping.
- Atraumatic fenestrated jaws provide a defined grasping profile for neurosurgical procedures.
- Straight design supports a specialized working orientation within the operative field.
- Suitable for neurosurgical and general surgery applications requiring a straight forceps.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 9″ Babcock Tissue Forceps is a specialized neurosurgical instrument designed for atraumatic grasping of delicate tissues such as intestines and tubular structures. Its smooth, fenestrated jaws provide a secure control without crushing, making it ideal for abdominal and general surgery.
With an overall length of 9 inches and a secure ratchet locking mechanism, this forceps provides a defined grasping profile for neurosurgical applications. The ergonomic design allows the working end to approach delicate tissues from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 9-inch overall length for balanced reach and control.
- Atraumatic, fenestrated jaws provide a secure grasping profile.
- Ergonomic design for specialized working orientation.
- Designed for delicate tissue handling.
- Suitable for neurosurgical and general surgery applications.
- Supports positioning of the working end within the operative field.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Babcock Tissue Forceps |
| Overall Length | 9″ |
| Working End / Blade / Jaw | Atraumatic fenestrated jaws |
| Configuration | Straight |
| Primary Function | Tissue Grasping |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Neurosurgical / General Surgery |
The 9″ Babcock Tissue Forceps combines a 9-inch overall length with atraumatic fenestrated jaws and a straight configuration.
Its defined grasping profile is intended for delicate tissue handling in neurosurgical applications.
Design & Function
The Babcock Tissue Forceps features a straight working configuration designed to provide a specialized orientation during tissue grasping. The fenestrated jaw design can assist in positioning the working end according to the requirements of the operative field.
The atraumatic jaw profile provides a defined grasping profile, while the 9-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a straight instrument type.
Surgical Applications
The 9″ Babcock Tissue Forceps may be used for neurosurgical and general surgery applications involving atraumatic grasping of delicate tissues. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Babcock Tissue Forceps before use, paying particular attention to the working end, jaw alignment, and gripping surfaces. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Babcock Tissue Forceps appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Babcock Tissue Forceps?
The overall length is 9 inches.
2. What is the working end / blade or tip design of the instrument?
It features atraumatic fenestrated jaws.
3. Is this Babcock Tissue Forceps curved or straight?
It features a straight configuration.
4. What is a Babcock Tissue Forceps used for?
It is designed for controlled tissue grasping in neurosurgical applications.
5. What clinical advantage does the fenestrated jaw provide?
The fenestrated jaw provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and general surgery applications where a straight and atraumatic Babcock Tissue Forceps is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Babcock Tissue Forceps be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.