9″ Cooley Multi-Purpose Clamp – Angled 60°
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-31413
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-31413AISI 420 Martensitic

9″ Cooley Multi-Purpose Clamp 60° Angled

4.9 / 5.0•18 Verified OR Evaluations
$435.00$461.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $26.00 (6% OFF)
  • 9″ Cooley Multi-Purpose Clamp 60° Angled designed with an angled configuration for secure vessel occlusion.
  • 60° angled jaws provide a defined clamping profile for cardiovascular procedures.
  • Angled design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and vascular surgery applications requiring an angled clamp.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 9″ Cooley Multi-Purpose Clamp 60° Angled is a specialized cardiovascular instrument designed for secure vessel occlusion during surgical procedures. Its 60-degree angled jaws provide superior access and visibility, making it ideal for deep and challenging surgical fields.

With an overall length of 9 inches and a unique angled jaw design, this clamp provides a defined clamping profile for cardiovascular applications. The atraumatic jaw profile ensures protection of the vessels while maintaining a secure grip, supporting controlled manual manipulation during procedures.

Key Features

  • 9-inch overall length for enhanced reach and handling.
  • 60° angled jaws improve access in confined spaces.
  • Atraumatic jaw profile protects vessels during occlusion.
  • Designed for secure vessel occlusion in cardiovascular procedures.
  • Suitable for vascular and peripheral surgery applications.
  • Supports positioning of the jaws within the operative field.
  • Specialized Cooley pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeCooley Multi-Purpose Clamp
Overall Length9″
Working End / Blade / Jaw60° Angled Jaws
ConfigurationAngled
Primary FunctionVessel Occlusion
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular / Vascular Surgery

The 9″ Cooley Multi-Purpose Clamp 60° Angled combines a 9-inch overall length with 60° angled jaws.
Its defined clamping profile is intended for secure vessel occlusion in cardiovascular applications.

Design & Function

The Cooley Multi-Purpose Clamp features a 60° angled configuration designed to provide a specialized orientation during vascular procedures. The angled jaw design can assist in positioning the working end according to the requirements of the operative field.

The 60° jaw profile provides a defined clamping profile, while the 9-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring an angled instrument type.

Surgical Applications

The 9″ Cooley Multi-Purpose Clamp 60° Angled may be used for cardiovascular and vascular surgery applications involving secure vessel occlusion. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Cooley Multi-Purpose Clamp before use, paying particular attention to the jaw alignment and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Cooley Multi-Purpose Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Cooley Multi-Purpose Clamp?
The overall length is 9 inches.

2. What is the working end / blade or tip design of the instrument?
It features 60° angled jaws.

3. Is this Cooley Multi-Purpose Clamp curved or straight?
It features an angled configuration.

4. What is a Cooley Multi-Purpose Clamp used for?
It is designed for controlled vessel occlusion in cardiovascular applications.

5. What clinical advantage does the angled design provide?
The angled design provides a specialized working orientation for positioning the jaws within the operative field.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular surgery applications where an angled clamp is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Cooley Multi-Purpose Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.