
9 1/2″ Cooley Multi-Purpose Clamp 60°
Direct Manufacturer Pricing • Tax Exclusive
- 9 1/2″ Cooley Multi-Purpose Clamp 60° designed with an angled configuration for controlled manipulation and occlusion.
- 60° angled jaw provides a defined clamping profile for cardiovascular procedures.
- Angled design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and vascular surgery applications requiring an angled clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 9 1/2″ Cooley Multi-Purpose Clamp 60° is a specialized cardiovascular instrument designed for controlled manipulation and temporary occlusion of vascular structures during cardiovascular and vascular procedures. Its 60° configuration provides a distinct working orientation that can assist with positioning the working end within the operative field.
With an overall length of 9 1/2 inches, this clamp provides extended working reach for operative fields where additional access is required. The angled design allows the working end to approach vascular structures from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 9 1/2-inch overall length for extended reach in operative fields.
- 60° working angle provides a defined clamping profile.
- Angled configuration for specialized working orientation.
- Designed for controlled manipulation and temporary occlusion.
- Suitable for cardiovascular and vascular surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Cooley pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Cooley Multi-Purpose Clamp |
| Overall Length | 9 1/2″ |
| Working End / Blade / Jaw | 60° Angled Jaw |
| Configuration | Angled |
| Primary Function | Manipulation and Occlusion |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Vascular Surgery |
The 9 1/2″ Cooley Multi-Purpose Clamp 60° combines a 9 1/2-inch overall length with a 60° angled jaw.
Its defined working profile is intended for controlled manipulation and occlusion in cardiovascular applications.
Design & Function
The Cooley Multi-Purpose Clamp features a 60° angled configuration designed to provide a specialized orientation during vascular procedures. The angled jaw design can assist in positioning the working end according to the requirements of the operative field.
The 60° jaw profile provides a defined clamping profile, while the 9 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring an angled instrument type.
Surgical Applications
The 9 1/2″ Cooley Multi-Purpose Clamp 60° may be used for cardiovascular and vascular surgery applications involving manipulation and temporary occlusion of vascular structures. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Cooley Multi-Purpose Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Cooley Multi-Purpose Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Cooley Multi-Purpose Clamp?
The overall length is 9 1/2 inches.
2. What is the working end / blade or tip design of the instrument?
It features 60° angled jaw.
3. Is this Cooley Multi-Purpose Clamp curved or straight?
It features a 60° angled configuration.
4. What is a Cooley Multi-Purpose Clamp used for?
It is designed for controlled manipulation and occlusion in cardiovascular applications.
5. What clinical advantage does the angled design provide?
The angled design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular applications where a 60° angled clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Cooley Multi-Purpose Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
