9 1/2″ DeBakey Bahnson Clamp – Medium Curve
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-31420
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-31420AISI 420 Martensitic

9 1/2″ DeBakey Bahnson Clamp Medium Curve

4.9 / 5.0•18 Verified OR Evaluations
$320.00$356.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $36.00 (10% OFF)
  • 9 1/2″ DeBakey Bahnson Clamp Medium Curve designed with a curved configuration for controlled occlusion.
  • Medium curve jaw design provides a defined clamping profile for cardiovascular procedures.
  • Curved design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and vascular surgery applications requiring a curved clamp.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 9 1/2″ DeBakey Bahnson Clamp Medium Curve is a specialized cardiovascular instrument designed for controlled occlusion in deeper operative fields. Its medium curved jaws provide enhanced reach and visibility while maintaining atraumatic vessel control.

With an overall length of 9 1/2 inches and a medium curve jaw design, this clamp provides a defined clamping profile for cardiovascular applications. The ergonomic design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 9 1/2-inch overall length for controlled manual handling.
  • Medium curve jaw design provides a defined clamping profile.
  • Curved configuration for specialized working orientation.
  • Designed for controlled occlusion in vascular surgery.
  • Suitable for cardiovascular and peripheral vascular surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized DeBakey pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeDeBakey Bahnson Clamp
Overall Length9 1/2″
Working End / Blade / JawMedium curve jaw design
ConfigurationCurved
Primary FunctionControlled Occlusion
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular / Vascular Surgery

The 9 1/2″ DeBakey Bahnson Clamp Medium Curve combines a 9 1/2-inch overall length with a medium curve jaw design. Its defined working profile is intended for controlled occlusion in cardiovascular applications.

Design & Function

The DeBakey Bahnson Clamp features a medium curved working configuration designed to provide a specialized orientation during vascular procedures. The jaw design can assist in positioning the working end according to the requirements of the operative field.

The medium curve jaw profile provides a defined clamping profile, while the 9 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a curved instrument type.

Surgical Applications

The 9 1/2″ DeBakey Bahnson Clamp Medium Curve may be used for cardiovascular and peripheral vascular surgery applications involving controlled occlusion. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the DeBakey Bahnson Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the DeBakey Bahnson Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Clamp?
The overall length is 9 1/2 inches.

2. What is the working end / blade or tip design of the instrument?
It features medium curve jaw design.

3. Is this Clamp curved or straight?
It features a curved configuration.

4. What is a DeBakey Bahnson Clamp used for?
It is designed for controlled occlusion in cardiovascular applications.

5. What clinical advantage does the medium curve provide?
The medium curve provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular surgery applications where a curved clamp is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the DeBakey Bahnson Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.