9 1/2″ Hajek Kofler Punch reversible jaw
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-47263
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ENTSKU: SP-47263AISI 420 Martensitic

9 1/2″ Hajek-Kofler Punch Reversible Jaw

4.9 / 5.0•18 Verified OR Evaluations
$900.00$920.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (2% OFF)
  • 9 1/2″ Hajek-Kofler Punch Reversible Jaw designed with a reversible configuration for versatile tissue excision.
  • Reversible jaw design provides a defined excision profile for ENT procedures.
  • Ergonomic design supports a specialized working orientation within the operative field.
  • Suitable for ENT and sinus surgery applications requiring a reversible punch.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 9 1/2″ Hajek-Kofler Punch Reversible Jaw is a specialized ENT instrument designed for versatile tissue excision in nasal and sinus surgery. Its reversible jaw allows the surgeon to adapt the instrument orientation intraoperatively, improving access and efficiency in varying anatomical situations.

With an overall length of 9 1/2 inches and a reversible jaw design, this punch provides a defined excision profile for ENT applications. The ergonomic handle ensures smooth actuation, balance, and precise tactile feedback, supporting controlled manual manipulation during procedures.

Key Features

  • 9 1/2-inch overall length for controlled manual handling.
  • Reversible jaw design provides a defined excision profile.
  • Ergonomic configuration for specialized working orientation.
  • Designed for versatile tissue excision in nasal and sinus surgery.
  • Suitable for ENT and sinus surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Hajek-Kofler pattern for professional ENT instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeHajek-Kofler Punch
Overall Length9 1/2″
Working End / Blade / JawReversible jaw design
ConfigurationReversible
Primary FunctionTissue Excision
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeENT / Sinus Surgery

The 9 1/2″ Hajek-Kofler Punch Reversible Jaw combines a 9 1/2-inch overall length with a reversible jaw design.
Its defined working profile is intended for versatile tissue excision in ENT applications.

Design & Function

The Hajek-Kofler Punch features a reversible working configuration designed to provide a specialized orientation during tissue excision. The jaw design can assist in positioning the working end according to the requirements of the operative field.

The reversible jaw profile provides a defined excision profile, while the 9 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a reversible punch.

Surgical Applications

The 9 1/2″ Hajek-Kofler Punch Reversible Jaw may be used for ENT and sinus surgery applications involving versatile tissue excision. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Hajek-Kofler Punch before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Hajek-Kofler Punch appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Hajek-Kofler Punch?
The overall length is 9 1/2 inches.

2. What is the working end / blade or tip design of the instrument?
It features a reversible jaw design.

3. Is this Hajek-Kofler Punch curved or straight?
It features a reversible configuration.

4. What is a Hajek-Kofler Punch used for?
It is designed for controlled tissue excision in ENT applications.

5. What clinical advantage does the reversible jaw provide?
The reversible jaw provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for ENT surgery?
It may be used in ENT and sinus surgery applications where a reversible punch is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Hajek-Kofler Punch be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.