
9 5/8″ DeBakey Acutely Curved Clamp
Direct Manufacturer Pricing • Tax Exclusive
- 9 5/8″ DeBakey Acutely Curved Clamp designed with an acutely curved configuration for controlled manipulation and occlusion.
- Acutely Curved Jaw provides a defined manipulation profile for cardiovascular procedures.
- Acutely curved design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and vascular surgery applications requiring an acutely curved clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 9 5/8″ DeBakey Acutely Curved Clamp is a specialized cardiovascular instrument designed for controlled manipulation and temporary occlusion of vascular structures during cardiovascular and vascular procedures. Its acutely curved configuration provides a pronounced working orientation that can assist with positioning the working end within the operative field.
With an overall length of 9 5/8 inches and a defined working profile, this clamp provides an extended reach for operative fields where additional access is required. The acutely curved design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 9 5/8-inch overall length for extended reach and controlled handling.
- Acutely curved configuration provides a pronounced working orientation.
- Designed for controlled manipulation and temporary occlusion of vascular structures.
- Suitable for cardiovascular and vascular surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized DeBakey pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | DeBakey Acutely Curved Clamp |
| Overall Length | 9 5/8″ |
| Working End / Blade / Jaw | Acutely Curved Jaw |
| Configuration | Acutely Curved |
| Primary Function | Controlled Manipulation and Occlusion |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Vascular Surgery |
The 9 5/8″ DeBakey Acutely Curved Clamp combines a 9 5/8-inch overall length with an acutely curved jaw configuration.
Its defined working profile is intended for controlled manipulation and occlusion in cardiovascular applications.
Design & Function
The DeBakey Acutely Curved Clamp features an acutely curved working configuration designed to provide a specialized orientation during vascular procedures. The jaw design can assist in positioning the working end according to the requirements of the operative field.
The acutely curved jaw profile provides a defined manipulation profile, while the 9 5/8-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring an acutely curved instrument.
Surgical Applications
The 9 5/8″ DeBakey Acutely Curved Clamp may be used for cardiovascular and vascular surgery applications involving controlled manipulation and temporary occlusion of vascular structures. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the DeBakey Acutely Curved Clamp before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the DeBakey Acutely Curved Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Clamp?
The overall length is 9 5/8 inches.
2. What is the working end / blade or tip design of the instrument?
It features Acutely Curved Jaw.
3. Is this Clamp curved or straight?
It features an Acutely Curved configuration.
4. What is a Clamp used for?
It is designed for controlled manipulation and occlusion in cardiovascular applications.
5. What clinical advantage does the acutely curved design provide?
The acutely curved design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular surgery applications where an acutely curved clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
