
9 cm Glover Bulldog Clamp Curved Jaws 4 cm
Direct Manufacturer Pricing • Tax Exclusive
- 9 cm Glover Bulldog Clamp designed with a curved configuration for temporary vessel occlusion.
- 4 cm jaw length provides a defined clamping profile for cardiovascular procedures.
- Curved design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and peripheral surgery applications requiring a curved clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 9 cm Glover Bulldog Clamp is a specialized cardiovascular instrument designed for temporary occlusion during cardiovascular and peripheral procedures. Its curved jaws provide a distinct working orientation that can assist with positioning the clamp within the operative field.
With an overall length of 9 cm and a 4 cm jaw length, this clamp provides a defined clamping profile for vascular applications. The curved design allows the working end to approach vessels from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 9 cm overall length for controlled manual handling.
- 4 cm jaw length provides a defined clamping profile.
- Curved configuration for specialized working orientation.
- Designed for temporary vessel occlusion.
- Suitable for cardiovascular and peripheral surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Glover pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Glover Bulldog Clamp |
| Overall Length | 9 cm |
| Working End / Blade / Jaw | 4 cm Curved Jaws |
| Configuration | Curved |
| Primary Function | Temporary Vessel Occlusion |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Peripheral Surgery |
The 9 cm Glover Bulldog Clamp combines a 9 cm overall length with a 4 cm jaw length and curved configuration.
Its defined working profile is intended for temporary vessel occlusion in cardiovascular applications.
Design & Function
The Glover Bulldog Clamp features a curved working configuration designed to provide a specialized orientation during vascular procedures. The jaw design can assist in positioning the clamp according to the requirements of the operative field.
The 4 cm jaw length provides a defined clamping profile, while the 9 cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a curved clamp.
Surgical Applications
The 9 cm Glover Bulldog Clamp may be used for cardiovascular and peripheral surgery applications involving temporary vessel occlusion. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Glover Bulldog Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Glover Bulldog Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Glover Bulldog Clamp?
The overall length is 9 cm.
2. What is the working end / blade or tip design of the instrument?
It features 4 cm curved jaws.
3. Is this Glover Bulldog Clamp curved or straight?
It features a curved configuration.
4. What is a Glover Bulldog Clamp used for?
It is designed for controlled temporary vessel occlusion in cardiovascular applications.
5. What clinical advantage does the curved design provide?
The curved design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and peripheral surgery applications where a curved clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Glover Bulldog Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
