9cm Glover Bulldog Clamp Curved Jaws 4cm
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-46455
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ClampsSKU: SP-46455AISI 420 Martensitic

9cm Glover Bulldog Clamp Curved Jaws 4cm

4.9 / 5.0•18 Verified OR Evaluations
$100.00$120.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (17% OFF)

The 9cm Glover Bulldog Clamp with Curved Jaws is a specialized surgical instrument designed for temporary vascular occlusion in procedures requiring controlled clamping. Its curved jaw configuration supports access to selected anatomical areas, while the compact 9cm overall length offers convenient handling in suitable surgical settings.

Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 9cm Glover Bulldog Clamp Curved Jaws 4cm is a vascular surgical instrument intended for applications that require temporary clamping of blood vessels. Recognized by its compact overall length and curved jaw design, this instrument is suited to specialized surgical environments where controlled vessel occlusion is required.

Bulldog clamps are used in vascular procedures to temporarily restrict blood flow through a selected vessel. The Glover pattern is associated with vascular clamping instruments, but the precise application, clamping force, and vessel compatibility of this specific model should be confirmed with the manufacturer or supplier before clinical use.

Design and Features

This Glover Bulldog Clamp features a curved jaw configuration intended to help accommodate selected vessel positions and surgical access requirements. The curved profile may assist with positioning where a straight jaw design is less suitable, depending on the anatomy and procedure.

With an overall length of 9cm, the instrument offers a compact format for appropriate surgical applications. The listed jaw length is 4cm; buyers should verify whether this measurement refers to the effective clamping surface, total jaw section, or another manufacturer-defined dimension.

The instrument's exact locking mechanism, spring tension, jaw serration pattern, and clamping pressure are not specified in the product title. These details should be checked against the supplier's technical specifications to ensure the clamp is appropriate for the intended procedure.

Intended Surgical Applications

Glover Bulldog clamps are generally associated with vascular surgery and temporary blood-vessel occlusion. Depending on the specific model and its verified performance characteristics, a curved-jaw configuration may be considered for procedures where the vessel's position or the required approach favors a curved instrument.

Potential application areas may include selected vascular procedures requiring temporary vessel control. However, this product's exact approved or recommended uses should be confirmed with the manufacturer. Instrument selection must account for vessel size, tissue sensitivity, required occlusion, and the surgeon's established technique.

Handling and Instrument Selection

Selecting the appropriate bulldog clamp requires more than matching the instrument's overall length. The jaw profile, effective clamping length, closing pressure, and compatibility with the target vessel are important considerations.

Before use, inspect the clamp for alignment, smooth movement, secure closure, and any visible damage. Confirm that the curved jaws meet evenly and that the instrument performs according to the manufacturer's requirements. Do not use an instrument that shows deformation, corrosion, damaged components, or inconsistent clamping action.

Material, Cleaning, and Sterilization

The material composition of this specific 9cm Glover Bulldog Clamp is not provided in the product title. Confirm the instrument's construction material, reusable or single-use status, and compatibility with the facility's validated cleaning and sterilization procedures before purchase and use.

If supplied as a reusable surgical instrument, follow the manufacturer's instructions for cleaning, inspection, disinfection, sterilization, maintenance, and storage. Do not assume that a particular sterilization method is suitable without confirming the product's instructions for use.

Choosing the Right Glover Bulldog Clamp

When choosing a Glover Bulldog Clamp, compare the required overall length, jaw curvature, effective jaw length, and clamping characteristics. The 9cm version with curved jaws and a listed 4cm jaw length may suit requirements where those dimensions match the intended application.

Confirm the actual jaw measurements and clamping performance with the supplier before ordering. This helps ensure the selected instrument matches the procedural requirements and the healthcare facility's instrument standards.

Key Features

  • Glover-pattern bulldog vascular clamp

  • Curved jaw configuration

  • Listed overall length of 9cm

  • Listed jaw length of 4cm

  • Designed for temporary vessel clamping in appropriate surgical applications

  • Compact instrument format

  • Intended for specialized vascular instrument requirements

  • Jaw alignment and clamping performance should be verified before use

  • Material composition not specified in the supplied product title

  • Cleaning and sterilization requirements should follow manufacturer instructions

Product Specifications

SpecificationDetails
Product NameGlover Bulldog Clamp
Instrument TypeBulldog clamp
Instrument CategoryVascular surgical instrument
Overall Length9cm
Jaw Length4cm, as listed in the product title
Jaw ConfigurationCurved
Primary FunctionTemporary vessel clamping, subject to model specifications
MaterialNot specified
Jaw SurfaceNot specified
Locking MechanismNot specified
Reusable or Single-UseConfirm with supplier
Sterilization CompatibilityFollow manufacturer instructions
Model NumberNot provided

Frequently Asked Questions

1. What is a 9cm Glover Bulldog Clamp used for?

Bulldog clamps are generally used to temporarily occlude blood vessels during selected surgical procedures. Confirm the intended application of this specific model with the manufacturer.

2. What is the overall length of this Glover Bulldog Clamp?

The overall length listed in the product title is 9cm.

3. Does this clamp have curved jaws?

Yes. The product title specifies a curved jaw configuration.

4. What does the 4cm jaw measurement mean?

The title lists a jaw length of 4cm. The precise measurement reference should be confirmed with the supplier because manufacturers may define jaw dimensions differently.

5. Is this clamp suitable for vascular surgery?

Glover bulldog clamps are associated with vascular clamping. Suitability for a particular procedure depends on the model's clamping pressure, jaw design, vessel compatibility, and manufacturer guidance.

6. What material is the clamp made from?

The material is not specified in the supplied product title. Contact the supplier for the exact material and any applicable material documentation.

7. Can the Glover Bulldog Clamp be sterilized?

Sterilization compatibility depends on the instrument's material, construction, and intended use. Follow the manufacturer's validated reprocessing instructions.

8. How should this clamp be inspected before use?

Check the jaw alignment, closing action, surface condition, and overall integrity according to the manufacturer's inspection guidance. Do not use a damaged or malfunctioning instrument.

9. How do I choose the correct bulldog clamp?

Consider the vessel size, required occlusion, jaw curvature, effective jaw length, and clamping characteristics. Confirm these specifications with the supplier before selecting an instrument.

10. Are model-specific specifications available?

Specifications such as material, jaw pressure, locking design, and sterilization compatibility were not included in the supplied title. Request the manufacturer's technical data for confirmation.