9″ Hajek Kofler Thru-Cutting Punch 2x3mm jaws
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-48168
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ENTSKU: SP-48168AISI 420 Martensitic

9″ Hajek Kofler Thru-Cutting Punch 2x3mm Jaws

4.9 / 5.0•18 Verified OR Evaluations
$750.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

  • 9″ Hajek Kofler Thru-Cutting Punch 2x3mm Jaws designed with a thru-cutting configuration for controlled cartilage excision.
  • 2×3 mm jaw size provides a defined cutting profile for ENT procedures.
  • Thru-cutting design supports a specialized working orientation within the operative field.
  • Suitable for ENT and nasal surgery applications requiring a thru-cutting instrument.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 9″ Hajek Kofler Thru-Cutting Punch 2x3mm Jaws is a specialized ENT instrument designed for controlled intranasal and septal cartilage excision. Its 2×3mm jaws provide a distinct working orientation that can assist with positioning the cutting end within the operative field.

With an overall length of 9 inches and a 2×3 mm jaw size, this Thru-Cutting Punch provides a defined cutting profile for ENT applications. The thru-cutting design allows the working end to approach cartilage from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 9-inch overall length for controlled manual handling.
  • 2×3 mm jaw size provides a defined cutting profile.
  • Thru-cutting design for specialized working orientation.
  • Designed for controlled cartilage excision.
  • Suitable for ENT and nasal surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Hajek Kofler pattern for professional ENT instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeHajek Kofler Thru-Cutting Punch
Overall Length9″
Working End / Blade / Jaw2×3 mm
ConfigurationThru-Cutting
Primary FunctionCartilage Excision
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeENT / Nasal Surgery

The 9″ Hajek Kofler Thru-Cutting Punch 2x3mm Jaws combines a 9-inch overall length with a 2×3 mm jaw size and thru-cutting design.
Its defined working profile is intended for controlled cartilage excision in ENT applications.

Design & Function

The Hajek Kofler Thru-Cutting Punch features a thru-cutting working configuration designed to provide a specialized orientation during cartilage excision. The jaw design can assist in positioning the cutting end according to the requirements of the operative field.

The 2×3 mm jaw profile provides a defined cutting profile, while the 9-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a thru-cutting instrument.

Surgical Applications

The 9″ Hajek Kofler Thru-Cutting Punch 2x3mm Jaws may be used for ENT and nasal surgery applications involving controlled cartilage excision. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Hajek Kofler Thru-Cutting Punch before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Hajek Kofler Thru-Cutting Punch appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Thru-Cutting Punch?
The overall length is 9 inches.

2. What is the working end / blade or tip design of the instrument?
It features 2×3 mm jaws.

3. Is this Thru-Cutting Punch curved or straight?
It features a thru-cutting configuration.

4. What is a Thru-Cutting Punch used for?
It is designed for controlled cartilage excision in ENT applications.

5. What clinical advantage does the thru-cutting design provide?
The thru-cutting design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for ENT surgery?
It may be used in ENT and nasal surgery applications where a thru-cutting instrument is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Thru-Cutting Punch be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.