9″ Jacobson “Heavy” Needle Holder – GG w/ lock
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-37223
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-37223AISI 420 Martensitic

9″ Jacobson Needle Holder Heavy with Lock

4.9 / 5.0•18 Verified OR Evaluations
$735.00$774.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $39.00 (5% OFF)
  • 9″ Jacobson Needle Holder Heavy with Lock designed with a locking configuration for reliable needle control during suturing.
  • Heavy-duty GG jaw design provides a defined gripping profile for cardiovascular procedures.
  • Locking design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and suturing applications requiring a reliable needle holder.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 9″ Jacobson Needle Holder Heavy with Lock is a specialized cardiovascular instrument designed for reliable needle control during demanding suturing tasks. Its heavy-duty construction provides added strength and stability, while the GG jaw pattern ensures a firm, slip-resistant hold on needles to minimize rotation and maintain accuracy.

With an overall length of 9 inches and a robust locking mechanism, this needle holder provides consistent control throughout prolonged procedures. The ergonomic design allows the working end to approach the surgical site with precision, supporting controlled manual manipulation during suturing.

Key Features

  • 9-inch overall length for enhanced handling and control.
  • Heavy-duty jaw design provides a defined gripping profile.
  • Integrated locking mechanism for secure needle retention.
  • Designed for reliable needle control during suturing.
  • Suitable for cardiovascular surgical applications.
  • Supports consistent control throughout prolonged procedures.
  • Specialized Jacobson pattern for professional surgical instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeJacobson Needle Holder
Overall Length9″
Working End / Blade / JawHeavy-duty GG jaw
ConfigurationLocking
Primary FunctionNeedle Control and Suturing
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular

The 9″ Jacobson Needle Holder Heavy with Lock combines a 9-inch overall length with a heavy-duty jaw design and locking configuration.
Its defined working profile is intended for reliable needle control in cardiovascular applications.

Design & Function

The Jacobson Needle Holder features a locking configuration designed to provide secure needle retention during suturing. The heavy-duty jaw design can assist in positioning the needle according to the requirements of the surgical field.

The heavy-duty jaw profile provides a defined gripping profile, while the 9-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a reliable needle holder.

Surgical Applications

The 9″ Jacobson Needle Holder Heavy with Lock may be used for cardiovascular and suturing applications involving precise needle control. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the needle holder before use, paying particular attention to the jaw alignment and locking mechanism. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the needle holder appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Needle Holder?
The overall length is 9 inches.

2. What is the working end / blade or tip design of the instrument?
It features heavy-duty GG jaw.

3. Is this Needle Holder curved or straight?
It features a locking configuration.

4. What is a Needle Holder used for?
It is designed for controlled needle control and suturing in cardiovascular applications.

5. What clinical advantage does the locking mechanism provide?
The locking mechanism provides secure needle retention for enhanced control during procedures.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and suturing applications where a reliable needle holder is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Needle Holder be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.