Anteater Narrow Muscle Blade – 3cm pair
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-53898
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
RetractorsSKU: SP-53898AISI 420 Martensitic

3cm Anteater Muscle Blade Pair

4.9 / 5.0•18 Verified OR Evaluations
$575.00$595.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (3% OFF)
  • 3cm Anteater Muscle Blade Pair designed with a straight configuration for controlled tissue retraction.
  • Narrow blade profile provides a defined retraction profile for general and orthopedic procedures.
  • Straight design supports a specialized working orientation within the operative field.
  • Suitable for general and orthopedic surgery applications requiring a straight muscle blade.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 3cm Anteater Muscle Blade Pair is a specialized surgical instrument designed for precise retraction in very shallow or confined operative fields. Its compact 3cm length allows accurate placement with minimal tissue disruption, while the narrow blade profile minimizes trauma to surrounding structures.

Constructed from high-quality titanium, the blades provide durability, corrosion resistance, and consistent performance through repeated sterilization cycles. Ergonomic handles enhance surgeon control during procedures.

Key Features

  • 3cm overall length for precise retraction in confined spaces.
  • Narrow blade profile minimizes trauma to surrounding tissues.
  • Ergonomic handle design enhances surgeon control.
  • Designed for controlled tissue retraction.
  • Suitable for general and orthopedic surgery applications.
  • Supports positioning of the blades within the operative field.
  • Specialized Anteater pattern for professional surgical instrument sets.
  • Corrosion-resistant titanium construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeAnteater Muscle Blade
Overall Length3cm
Working End / Blade / JawNarrow blade profile
ConfigurationStraight
Primary FunctionTissue Retraction
MaterialTitanium
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeGeneral / Orthopedic Surgery

The 3cm Anteater Muscle Blade Pair combines a 3cm overall length with a narrow blade profile and straight configuration.
Its defined working profile is intended for controlled tissue retraction in general and orthopedic surgery applications.

Design & Function

The Anteater Muscle Blade features a straight working configuration designed to provide a specialized orientation during tissue retraction. The narrow blade design can assist in positioning the working end according to the requirements of the operative field.

The narrow blade profile provides a defined retraction profile, while the 3cm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for general and orthopedic procedures requiring a straight instrument type.

Surgical Applications

The 3cm Anteater Muscle Blade Pair may be used for general and orthopedic surgery applications involving precise tissue retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Anteater Muscle Blade before use, paying particular attention to the working end and blade alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Anteater Muscle Blade appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Muscle Blade?
The overall length is 3cm.

2. What is the working end / blade design of the instrument?
It features a narrow blade profile.

3. Is this Muscle Blade curved or straight?
It features a straight configuration.

4. What is a Muscle Blade used for?
It is designed for controlled tissue retraction in general and orthopedic surgery applications.

5. What clinical advantage does the narrow blade provide?
The narrow blade provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for general surgery?
It may be used in general and orthopedic surgery applications where a straight muscle blade is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Muscle Blade be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.