B Single Clamp 0.4-1.0mm Pair
Direct Manufacturer Pricing • Tax Exclusive
- B Single Clamp 0.4-1.0mm Pair designed with a standard configuration for precise vessel approximation.
- 0.4-1.0 mm working end provides a defined clamping profile for cardiovascular procedures.
- Atraumatic design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and microvascular applications requiring a precision clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The B Single Clamp 0.4-1.0mm Pair is a specialized cardiovascular instrument designed for fine vessel approximation and control in microvascular procedures. Its precise 0.4–1.0 mm range provides a distinct working orientation that can assist with positioning the clamps within the operative field.
With an overall length suitable for delicate surgical work, this clamp pair provides a defined clamping profile for microvascular applications. The atraumatic design allows the working ends to approach delicate tissues with minimal trauma, supporting controlled manual manipulation during procedures.
Key Features
- Matched pair supplied for enhanced surgical efficiency.
- Fine 0.4–1.0 mm range for microvascular precision.
- Atraumatic design for delicate tissues.
- Designed for stable and controlled vessel approximation.
- Precision-engineered stainless steel construction.
- Supports positioning of the working ends within the operative field.
- Specialized clamp design for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | B Single Clamp |
| Overall Length | Standard Length |
| Working End / Blade / Jaw | 0.4-1.0 mm |
| Configuration | Standard |
| Primary Function | Vessel Approximation |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular / Microvascular Surgery |
The B Single Clamp 0.4-1.0mm Pair combines a standard length with a 0.4-1.0 mm working end.
Its defined clamping profile is intended for precise vessel approximation in cardiovascular applications.
Design & Function
The B Single Clamp features a standard working configuration designed to provide a specialized orientation during microvascular procedures. The atraumatic design can assist in positioning the clamps according to the requirements of the operative field.
The 0.4-1.0 mm working end provides a defined clamping profile, while the standard length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a precision clamp.
Surgical Applications
The B Single Clamp 0.4-1.0mm Pair may be used for cardiovascular and microvascular applications involving fine vessel approximation. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the B Single Clamp before use, paying particular attention to the working ends and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the B Single Clamp appropriately to protect its working ends and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this B Single Clamp?
The overall length is Standard Length.
2. What is the working end / blade or tip design of the instrument?
It features 0.4-1.0 mm working end.
3. Is this B Single Clamp curved or straight?
It features a standard configuration.
4. What is a B Single Clamp used for?
It is designed for controlled vessel approximation in cardiovascular applications.
5. What clinical advantage does the atraumatic design provide?
The atraumatic design provides a specialized working orientation for positioning the working ends within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and microvascular applications where a precision clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the B Single Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.