Ballenger Swivel Knife bay 5mm blade
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-48421
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ENTSKU: SP-48421AISI 420 Martensitic

5mm Ballenger Swivel Knife Bay Blade

4.9 / 5.0•18 Verified OR Evaluations
$185.00$204.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $19.00 (9% OFF)
  • 5mm Ballenger Swivel Knife Bay Blade designed with a swivel configuration for controlled incisions.
  • 5 mm blade width provides a defined cutting profile for ENT procedures.
  • Swivel design supports a specialized working orientation within the operative field.
  • Suitable for ENT and nasal surgery applications requiring a swivel knife.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 5mm Ballenger Swivel Knife Bay Blade is a specialized ENT instrument designed for controlled, precise incisions in intranasal and septal procedures requiring a larger cutting surface. Its swivel mechanism allows surgeons to adjust the angle for optimal access to confined areas while maintaining full control over depth and precision.

With an overall length of and a 5 mm blade width, this Swivel Knife provides a defined cutting profile for ENT applications. The ergonomic design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • for controlled manual handling.
  • 5 mm blade width provides a defined cutting profile.
  • Swivel configuration for specialized working orientation.
  • Designed for controlled incisions in intranasal and septal procedures.
  • Suitable for ENT applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Ballenger pattern for professional ENT instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeBallenger Swivel Knife
Overall Length
Working End / Blade / Jaw5 mm Bay Blade
ConfigurationSwivel
Primary FunctionControlled Incisions
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeENT

The 5mm Ballenger Swivel Knife Bay Blade combines a overall length with a 5 mm blade width and swivel configuration.
Its defined working profile is intended for controlled incisions in ENT applications.

Design & Function

The Ballenger Swivel Knife features a swivel working configuration designed to provide a specialized orientation during intranasal and septal procedures. The blade design can assist in positioning the working end according to the requirements of the operative field.

The 5 mm blade width provides a defined cutting profile, while the allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a swivel knife.

Surgical Applications

The 5mm Ballenger Swivel Knife Bay Blade may be used for ENT and nasal surgery applications involving precise incisions. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Ballenger Swivel Knife before use, paying particular attention to the working end, blade alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Ballenger Swivel Knife appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Ballenger Swivel Knife?
The overall length is .

2. What is the working end / blade or tip design of the instrument?
It features 5 mm Bay Blade.

3. Is this Ballenger Swivel Knife curved or straight?
It features a Swivel configuration.

4. What is a Ballenger Swivel Knife used for?
It is designed for controlled incisions in ENT applications.

5. What clinical advantage does the swivel design provide?
The swivel design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for ENT surgery?
It may be used in ENT and nasal surgery applications where a swivel knife is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Ballenger Swivel Knife be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.