Bayonet Curette – 1.8 mm Forward Straight, Panther
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-29323
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
NeurosurgicalSKU: SP-29323AISI 420 Martensitic

1.8 mm Panther Bayonet Curette Forward Straight

4.9 / 5.0•18 Verified OR Evaluations
$412.00$512.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $100.00 (20% OFF)
  • 1.8 mm Panther Bayonet Curette designed with a forward straight configuration for accurate bone scraping and tissue removal.
  • 1.8 mm working width provides a defined scraping profile for neurosurgical procedures.
  • Forward straight design supports a specialized working orientation within the operative field.
  • Suitable for neurosurgical and spinal surgery applications requiring a forward straight curette.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 1.8 mm Panther Bayonet Curette is a specialized neurosurgical instrument designed for accurate bone scraping and tissue removal. Its forward straight tip provides precise access in narrow operative fields, making it ideal for minimally invasive surgeries.

With an overall length of and a 1.8 mm working width, this curette provides a defined scraping profile for neurosurgical applications. The forward straight design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • for controlled manual handling.
  • 1.8 mm working width provides a defined scraping profile.
  • Forward straight configuration for specialized working orientation.
  • Designed for accurate bone scraping and tissue removal.
  • Suitable for neurosurgical applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Panther pattern for professional neurosurgical instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypePanther Bayonet Curette
Overall Length
Working End / Blade / Jaw1.8 mm
ConfigurationForward Straight
Primary FunctionBone Scraping and Tissue Removal
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeNeurosurgical

The 1.8 mm Panther Bayonet Curette combines a overall length with a 1.8 mm working width and forward straight configuration.
Its defined working profile is intended for accurate bone scraping and tissue removal in neurosurgical applications.

Design & Function

The Panther Bayonet Curette features a forward straight working configuration designed to provide a specialized orientation during surgical procedures. The forward straight tip can assist in positioning the working end according to the requirements of the operative field.

The 1.8 mm working dimension provides a defined scraping profile, while the allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a forward straight instrument type.

Surgical Applications

The 1.8 mm Panther Bayonet Curette may be used for neurosurgical and spinal surgery applications involving accurate bone scraping and tissue removal. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the bayonet curette before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the bayonet curette appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Bayonet Curette?
The overall length is .

2. What is the working end / blade or tip design of the instrument?
It features 1.8 mm working width.

3. Is this Bayonet Curette curved or straight?
It features a forward straight configuration.

4. What is a Bayonet Curette used for?
It is designed for controlled bone scraping and tissue removal in neurosurgical applications.

5. What clinical advantage does the forward straight design provide?
The forward straight design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for neurosurgical surgery?
It may be used in neurosurgical and spinal surgery applications where a forward straight bayonet curette is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Bayonet Curette be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.