Bayonet Shaft – 8mm downcutting blade
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-43847
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ENTSKU: SP-43847AISI 420 Martensitic

8mm Bayonet Shaft Downcutting Blade

4.9 / 5.0•18 Verified OR Evaluations
$100.00$118.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $18.00 (15% OFF)
  • 8mm Bayonet Shaft Downcutting Blade designed with a bayonet configuration for precise removal and shaping of bone or tissue.
  • 8 mm downcutting blade provides a defined cutting profile for ENT procedures.
  • Bayonet design supports a specialized working orientation within the operative field.
  • Suitable for ENT and otologic surgery applications requiring a bayonet instrument type.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 8mm Bayonet Shaft Downcutting Blade is a specialized ENT instrument designed for precise removal, shaping, and contouring of bone or tissue in confined surgical spaces. Its downcutting blade geometry provides a distinct working orientation that can assist with controlled excision while minimizing trauma to surrounding delicate structures.

With an overall length of and an 8 mm blade width, this Bayonet Shaft provides a defined cutting profile for ENT applications. The ergonomic design allows the working end to approach anatomical obstructions from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • for controlled manual handling.
  • 8 mm blade width provides a defined cutting profile.
  • Bayonet configuration for specialized working orientation.
  • Designed for precise removal and shaping of bone or tissue.
  • Suitable for ENT and otologic surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Bayonet pattern for professional ENT instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeBayonet Shaft Downcutting Blade
Overall Length
Working End / Blade / Jaw8 mm downcutting blade
ConfigurationBayonet
Primary FunctionBone and Tissue Shaping
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeENT / Otologic Surgery

The 8mm Bayonet Shaft Downcutting Blade combines a overall length with an 8 mm blade width and bayonet configuration.
Its defined working profile is intended for precise removal and shaping of bone or tissue in ENT applications.

Design & Function

The Bayonet Shaft Downcutting Blade features a bayonet working configuration designed to provide a specialized orientation during otologic procedures. The downcutting blade design can assist in positioning the working end according to the requirements of the operative field.

The 8 mm blade width provides a defined cutting profile, while the allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a bayonet instrument type.

Surgical Applications

The 8mm Bayonet Shaft Downcutting Blade may be used for ENT and otologic surgery applications involving precise removal and shaping of bone or tissue. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Bayonet Shaft Downcutting Blade before use, paying particular attention to the working end, blade alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Bayonet Shaft appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Bayonet Shaft Downcutting Blade?
The overall length is .

2. What is the working end / blade or tip design of the instrument?
It features 8 mm downcutting blade.

3. Is this Bayonet Shaft Downcutting Blade curved or straight?
It features a bayonet configuration.

4. What is a Bayonet Shaft Downcutting Blade used for?
It is designed for controlled bone and tissue shaping in ENT applications.

5. What clinical advantage does the downcutting blade provide?
The downcutting blade provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for ENT surgery?
It may be used in ENT and otologic applications where a bayonet configuration instrument type is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Bayonet Shaft Downcutting Blade be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.