4
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-97565
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
General Surgery InstrumentsSKU: SP-97565AISI 420 Martensitic

Bhargava Modular Offset Cup Liner Impactor

4.9 / 5.0•18 Verified OR Evaluations
$300.00$340.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $40.00 (12% OFF)
The Bhargava Modular Offset Cup Liner Impactor is designed to help impact an acetabular cup liner during minimally invasive direct anterior and MIS posterior approach THR. Its modular offset design accepts interchangeable heads that fit securely onto the impactor end, helping avoid edge loading and improper liner seating associated with straight impactors.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Bhargava Modular Offset Cup Liner Impactor is a specialized orthopedic instrument designed to assist with acetabular cup liner impaction during minimally invasive total hip replacement procedures.

The instrument features a modular offset design with a working end that accepts individually interchangeable heads. These heads are sold separately and are designed to fit securely onto the impactor end.

The offset configuration provides an alternative approach compared with a straight impactor and is designed to help reduce the potential for edge loading and improper seating of the liner during the impaction process.

The instrument has an overall length of 15.85" (40.2 cm) and a 1" (2.54 cm) platform-end diameter.

Key Features

  • Designed for acetabular cup liner impaction
  • Intended for minimally invasive direct anterior and MIS posterior approach THR
  • Modular design accepts interchangeable impactor heads
  • Interchangeable heads are sold separately
  • Heads fit securely onto the impactor end
  • Offset configuration provides an alternative approach to a straight impactor
  • Designed to help avoid edge loading and improper liner seating
  • 15.85" (40.2 cm) overall length
  • 1" (2.54 cm) platform-end diameter

Modular Head System

The Bhargava Modular Offset Cup Liner Impactor is designed to be used with individual interchangeable heads. The heads are sold separately and attach securely to the impactor end.

This modular arrangement allows the appropriate head to be selected according to the acetabular cup liner being impacted.

Important: The interchangeable impactor heads are not included with the impactor unless specifically supplied as a separate component or set.

Offset Design

The instrument incorporates an offset shaft configuration rather than a straight impactor profile.

The offset working geometry is designed to provide a more suitable approach to the acetabular cup liner during minimally invasive hip procedures. This configuration can help the user position the impactor appropriately while maintaining access to the operative site.

Acetabular Cup Liner Impaction

The primary purpose of the instrument is to assist with controlled impaction of an acetabular cup liner.

The design is intended to help avoid situations where a straight impactor may contribute to edge loading or improper liner seating. The offset configuration provides an alternative working angle for positioning the interchangeable head against the liner.

Surgical Applications

The Bhargava Modular Offset Cup Liner Impactor is designed for:

  • Acetabular cup liner impaction
  • Total hip replacement procedures
  • Minimally invasive direct anterior approach THR
  • MIS posterior approach THR
  • Controlled positioning and seating of acetabular liners
  • Procedures requiring an offset cup liner impactor

The appropriate interchangeable head should be selected according to the compatible liner and surgical system being used.

Interchangeable Heads

The impactor is designed to work with individual interchangeable heads that are sold separately. The selected head fits onto the impactor end and provides the appropriate interface for the acetabular cup liner.

This modular approach allows one impactor body to be used with different compatible head configurations rather than requiring a completely separate impactor for every liner size.

Working-End Characteristics

The impactor has a specified 1" (2.54 cm) platform-end diameter. The modular end is designed to accept the appropriate interchangeable head.

The head attachment area should be checked before use to ensure the selected head is correctly fitted and securely seated.

Extended Overall Length

The impactor measures 15.85" (40.2 cm) overall. Its extended length, combined with the offset shaft, provides reach to the acetabular working area during minimally invasive hip procedures.

The overall design allows the handle end to remain accessible while the interchangeable head is positioned at the operative site.

Design and Function

The instrument consists of an elongated offset shaft with a platform end for attachment of the selected interchangeable head.

The general operating sequence involves:

  1. Select the appropriate compatible interchangeable head.
  2. Securely attach the head to the impactor end.
  3. Position the head against the acetabular cup liner.
  4. Confirm appropriate alignment and seating before impaction.
  5. Use the instrument according to the established surgical technique.

Technical Specifications

SpecificationDetails
Instrument NameBhargava Modular Offset Cup Liner Impactor
Product TypeSimple Product
Primary FunctionAcetabular Cup Liner Impaction
Overall Length15.85" (40.2 cm)
Platform End Diameter1" (2.54 cm)
DesignModular Offset
Head SystemInterchangeable
Interchangeable HeadsSold Separately
Intended ProceduresMinimally Invasive Direct Anterior and MIS Posterior Approach THR

Handling and Use Considerations

Ensure that the selected interchangeable head is compatible with the intended acetabular cup liner and is securely attached before use.

The impactor and head should be inspected before use for visible damage, secure attachment, and proper condition. The interchangeable head should be correctly seated on the impactor before applying any impaction force.

Follow the healthcare facility's established procedures for cleaning, inspection, sterilization, maintenance, and storage.

FAQs

What is the Bhargava Modular Offset Cup Liner Impactor used for?

It is designed to assist with acetabular cup liner impaction during total hip replacement procedures.

What surgical approaches is it designed for?

It is designed for minimally invasive direct anterior and MIS posterior approach THR.

What is the overall length?

The overall length is 15.85" (40.2 cm).

What is the platform-end diameter?

The platform-end diameter is 1" (2.54 cm).

Does the impactor include the interchangeable head?

The interchangeable heads are sold separately.

What is the purpose of the offset design?

The offset design provides an alternative approach to a straight impactor and is designed to help avoid edge loading and improper seating of the liner.