Biopsy Forceps 70° 4mm cup horizontal
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-47723
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ENTSKU: SP-47723AISI 420 Martensitic

4mm Biopsy Forceps 70° Horizontal

4.9 / 5.0•18 Verified OR Evaluations
$621.00$641.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (3% OFF)
  • 4mm Biopsy Forceps designed with a 70° horizontal configuration for targeted tissue sampling.
  • 4 mm cup provides a defined grasping profile for ENT procedures.
  • Angled design supports a specialized working orientation within the operative field.
  • Suitable for ENT and endoscopic applications requiring a biopsy forceps.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 4mm Biopsy Forceps is a specialized ENT instrument designed for targeted tissue sampling during endoscopic procedures. Its 70° horizontal angle provides a distinct working orientation that can assist with positioning the cup within tight anatomical areas.

With an overall length of and a 4 mm cup size, this biopsy forceps provides a defined grasping profile for ENT applications. The ergonomic design allows the working end to approach the anatomical target from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • 4 mm cup for reliable tissue sampling.
  • 70° horizontal angle for controlled access to tight spaces.
  • Ergonomic handle for smooth actuation and tactile control.
  • Designed for precise excision and secure handling.
  • Suitable for ENT and endoscopic applications.
  • Supports positioning of the working end within the operative field.
  • Corrosion-resistant surgical-grade stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeBiopsy Forceps
Overall Length
Working End / Blade / Jaw4 mm cup
Configuration70° Horizontal
Primary FunctionTissue Sampling
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeENT

The 4mm Biopsy Forceps combines a overall length with a 4 mm cup and a 70° horizontal angle.
Its defined working profile is intended for precise tissue sampling in ENT applications.

Design & Function

The Biopsy Forceps features a 70° horizontal configuration designed to provide a specialized orientation during tissue sampling. The angled design can assist in positioning the cup according to the requirements of the operative field.

The 4 mm cup provides a defined grasping profile, while the overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a biopsy forceps.

Surgical Applications

The 4mm Biopsy Forceps may be used for ENT and endoscopic applications involving targeted tissue sampling. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the biopsy forceps before use, paying particular attention to the working end and cup alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the biopsy forceps appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Biopsy Forceps?
The overall length is .

2. What is the working end / blade or tip design of the instrument?
It features 4 mm cup.

3. Is this Biopsy Forceps curved or straight?
It features a 70° horizontal configuration.

4. What is a Biopsy Forceps used for?
It is designed for controlled tissue sampling in ENT applications.

5. What clinical advantage does the angled design provide?
The angled design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for ENT surgery?
It may be used in ENT and endoscopic applications where a 70° horizontal biopsy forceps is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Biopsy Forceps be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.