
4″ Biopsy & Grasping Forceps 110° Vertical
Direct Manufacturer Pricing • Tax Exclusive
- 4″ Biopsy & Grasping Forceps designed with a vertical configuration for precise tissue sampling and secure grasping.
- 4 mm cup size provides a defined grasping profile for ENT procedures.
- Vertical design supports a specialized working orientation within the operative field.
- Suitable for ENT and nasal surgery applications requiring a specialized grasping instrument.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 4″ Biopsy & Grasping Forceps is a specialized ENT instrument designed for precise tissue sampling and secure grasping during nasal and sinus procedures. Its vertical angulation provides effective access to superior and lateral anatomical regions, while the cup-shaped jaws ensure reliable tissue capture with minimal trauma.
With an overall length of 4 inches and a 4 mm cup size, this forceps provides a defined grasping profile for ENT applications. The 110° vertical design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 4-inch overall length for controlled manual handling.
- 4 mm cup size provides a defined grasping profile.
- 110° vertical configuration for specialized working orientation.
- Designed for precise tissue sampling and secure grasping.
- Suitable for ENT and nasal surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Biopsy & Grasping pattern for professional ENT instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Biopsy & Grasping Forceps |
| Overall Length | 4″ |
| Working End / Blade / Jaw | 4 mm cup |
| Configuration | 110° Vertical |
| Primary Function | Tissue Sampling and Grasping |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | ENT / Nasal Surgery |
The 4″ Biopsy & Grasping Forceps combines a 4-inch overall length with a 4 mm cup and 110° vertical configuration.
Its defined working profile is intended for precise tissue sampling and secure grasping in ENT applications.
Design & Function
The Biopsy & Grasping Forceps features a 110° vertical working configuration designed to provide a specialized orientation during nasal and sinus procedures. The cup-shaped jaw design can assist in positioning the working end according to the requirements of the operative field.
The 4 mm cup provides a defined grasping profile, while the 4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a specialized grasping instrument.
Surgical Applications
The 4″ Biopsy & Grasping Forceps may be used for ENT and nasal surgery applications involving precise tissue sampling and secure grasping. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Biopsy & Grasping Forceps before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Biopsy & Grasping Forceps appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Biopsy & Grasping Forceps?
The overall length is 4 inches.
2. What is the working end / blade or tip design of the instrument?
It features 4 mm cup.
3. Is this Biopsy & Grasping Forceps curved or straight?
It features a 110° vertical configuration.
4. What is a Biopsy & Grasping Forceps used for?
It is designed for controlled tissue sampling and grasping in ENT applications.
5. What clinical advantage does the vertical design provide?
The vertical configuration provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for ENT surgery?
It may be used in ENT and nasal surgery applications where a 110° vertical Biopsy & Grasping Forceps is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Biopsy & Grasping Forceps be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
