
Blair Narrow Femoral Neck Elevator with Waist Pad
Direct Manufacturer Pricing • Tax Exclusive
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The Blair Narrow Femoral Neck Elevator with Waist Pad is a specialized orthopedic surgical instrument designed to assist surgeons with controlled elevation and exposure of the femoral neck during hip surgery. Its narrow working profile allows focused access around the proximal femur, making it suitable for procedures where space is limited and precise positioning is important.
The elevator incorporates a waist pad that helps distribute contact against the surrounding tissue and bone while supporting stable instrument placement. This design can help maintain controlled retraction during femoral exposure and reduce unnecessary movement of the instrument while the surgeon works around the hip joint.
Its narrow blade is particularly useful when access to the femoral neck requires a more concentrated working surface. The instrument can be used during procedures involving femoral neck exposure, proximal femoral preparation, hip reconstruction, and other orthopedic approaches where controlled elevation of tissue or bone is required. The configuration supports clear visualization of the operative field while helping protect surrounding soft tissues when properly positioned.
The ergonomic design provides a practical balance between reach, control, and visibility. The elongated shaft allows the surgeon to work at an appropriate depth while maintaining a secure grip on the instrument. The waist pad contributes additional stability at the working end, helping the elevator remain positioned against the intended anatomical area during manipulation.
Manufactured for professional surgical environments, the Blair Narrow Femoral Neck Elevator is typically produced from surgical-grade stainless steel. This material provides strength, corrosion resistance, and durability required for repeated clinical use when the instrument is properly cleaned, inspected, sterilized, and maintained according to applicable healthcare protocols.
The instrument is suitable for orthopedic hospitals, surgical centers, trauma units, and specialty practices performing hip and proximal femoral procedures. Its focused design makes it a useful addition to orthopedic instrument sets where controlled femoral neck exposure is required.
Proper handling is important to preserve the working edge, surface finish, and alignment of the elevator. After each procedure, the instrument should be cleaned according to the manufacturer's validated processing instructions, thoroughly inspected for damage or deformation, and sterilized using an appropriate validated method. Routine maintenance supports reliable performance and extends the service life of the instrument.
Key Features
- Narrow profile for focused femoral neck access
- Integrated waist pad for improved instrument stability
- Designed for controlled femoral elevation and exposure
- Suitable for orthopedic hip procedures
- Supports proximal femoral surgical access
- Long working design for deeper operative fields
- Ergonomic handling for controlled manipulation
- Manufactured from durable surgical-grade stainless steel
- Corrosion-resistant surface for repeated clinical use
- Reusable when properly cleaned and sterilized
- Suitable for orthopedic and trauma instrument sets
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Blair Narrow Femoral Neck Elevator with Waist Pad |
| Instrument Type | Femoral Neck Elevator |
| Design | Narrow |
| Working Feature | Waist Pad |
| Surgical Specialty | Orthopedic Surgery |
| Primary Application | Femoral Neck Exposure |
| Material | Surgical-Grade Stainless Steel |
| Reusable | Yes, when properly processed |
| Sterilization | Compatible with validated sterilization protocols |
| Use | Professional Surgical Procedures |
FAQs
What is a Blair Narrow Femoral Neck Elevator used for?
It is used to assist with controlled elevation and exposure of the femoral neck during orthopedic and hip surgical procedures.
What is the purpose of the waist pad?
The waist pad provides a broader contact area around the working portion of the instrument, helping improve stability and controlled positioning during use.
Why is the elevator designed with a narrow blade?
The narrow design allows more focused access around the femoral neck and proximal femur, particularly when the surgical field has limited working space.
Can this instrument be used in hip surgery?
Yes. It is designed for femoral neck exposure and can be incorporated into appropriate orthopedic hip and proximal femoral procedures.
What material is the Blair Femoral Neck Elevator made from?
Surgical-grade stainless steel is commonly used for this type of reusable orthopedic instrument because of its strength, corrosion resistance, and durability.
Is the Blair Femoral Neck Elevator reusable?
Yes, when manufactured as a reusable surgical instrument and processed according to validated cleaning, inspection, and sterilization procedures.
How should the instrument be sterilized?
It should be cleaned and sterilized according to the manufacturer's validated instructions and the healthcare facility's applicable sterilization protocol.
