
6 1/4″ Bowman Lacrimal Probe Sterling Size 0000/000
Direct Manufacturer Pricing • Tax Exclusive
- 6 1/4″ Bowman Lacrimal Probe Sterling Size 0000/000 designed with a straight configuration for probing and dilating.
- Sterling size 0000/000 provides a defined probing profile for ophthalmic procedures.
- Straight design supports a specialized working orientation within the operative field.
- Suitable for ophthalmic and lacrimal duct surgery applications requiring a straight instrument type.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 6 1/4″ Bowman Lacrimal Probe Sterling Size 0000/000 is a specialized ophthalmic instrument designed for probing and dilating the lacrimal canaliculi and nasolacrimal duct. Its slender, polished probe tip provides a smooth passage through the canaliculi, allowing for delicate exploration and irrigation of the lacrimal system without causing trauma.
With an overall length of 6 1/4 inches and a sterling-grade construction, this probe offers a defined profile for ophthalmic applications. The rigid yet lightweight shaft ensures control and tactile feedback during procedures, supporting precise manual manipulation.
Key Features
- 6 1/4-inch overall length for controlled manual handling.
- Sterling size 0000/000 provides a defined probing profile.
- Polished probe tip for smooth passage through the canaliculi.
- Designed for probing and dilating the lacrimal system.
- Suitable for ophthalmic and lacrimal duct surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Bowman pattern for professional ophthalmic instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Bowman Lacrimal Probe |
| Overall Length | 6 1/4″ |
| Working End / Blade / Jaw | Sterling size 0000/000 |
| Configuration | Straight |
| Primary Function | Probing and Dilating |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Ophthalmic / Lacrimal Duct Surgery |
The 6 1/4″ Bowman Lacrimal Probe Sterling Size 0000/000 combines a 6 1/4-inch overall length with a sterling size 0000/000 and straight configuration.
Its defined working profile is intended for probing and dilating in ophthalmic applications.
Design & Function
The Bowman Lacrimal Probe features a straight working configuration designed to provide a specialized orientation during lacrimal duct procedures. The polished probe tip can assist in positioning the working end according to the requirements of the operative field.
The sterling size 0000/000 provides a defined probing profile, while the 6 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ophthalmic procedures requiring a straight instrument type.
Surgical Applications
The 6 1/4″ Bowman Lacrimal Probe Sterling Size 0000/000 may be used for ophthalmic and lacrimal duct surgery applications involving probing and dilating actions. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Bowman Lacrimal Probe before use, paying particular attention to the working end and probe tip. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Bowman Lacrimal Probe appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Bowman Lacrimal Probe?
The overall length is 6 1/4 inches.
2. What is the working end / blade or tip design of the instrument?
It features sterling size 0000/000.
3. Is this Bowman Lacrimal Probe curved or straight?
It features a straight configuration.
4. What is a Bowman Lacrimal Probe used for?
It is designed for controlled probing and dilating in ophthalmic applications.
5. What clinical advantage does the polished probe tip provide?
The polished probe tip provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for ophthalmic surgery?
It may be used in ophthalmic and lacrimal duct applications where a straight Bowman Lacrimal Probe is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Bowman Lacrimal Probe be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
