45
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-79575
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
General Surgery InstrumentsSKU: SP-79575AISI 420 Martensitic

Breast retractors blade size 30mm x 150mm with teeth reusable with led light

4.9 / 5.0•18 Verified OR Evaluations
$220.00$250.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $30.00 (12% OFF)
The LED Breast Retractor features a 30 mm × 150 mm toothed blade designed for controlled tissue retraction and surgical exposure. Integrated LED illumination helps provide focused visibility during breast and plastic surgery procedures.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Breast Retractor with Teeth, LED Light, and 30 mm × 150 mm Blade is a specialized surgical instrument designed to assist with controlled tissue retraction and improved visualization during breast and plastic surgery procedures. Its toothed blade provides a secure tissue-engaging surface, while the integrated LED light helps illuminate the operative field.

The retractor features a 30 mm × 150 mm blade, offering a defined working surface for maintaining tissue exposure during surgery. The toothed configuration is designed to provide controlled engagement with tissue when appropriate for the surgical technique. Careful handling and appropriate positioning should always be used to minimize unnecessary tissue trauma.

Integrated LED illumination provides focused light close to the surgical field. This can help improve visualization of the operative area and reduce shadows that may occur with conventional overhead lighting. The illumination system should be checked before use to confirm proper function.

This breast retractor can support surgical exposure during a range of breast and plastic surgery procedures, including breast augmentation, breast reconstruction, breast reduction, mastopexy, and other procedures where controlled tissue retraction is required. The appropriate instrument size, position, and technique should be determined by the surgeon based on the procedure and patient anatomy.

The reusable design makes the instrument suitable for repeated clinical use when processed according to the manufacturer's validated instructions. After each procedure, the retractor should be thoroughly cleaned and inspected. Particular attention should be given to the toothed blade, blade edges, joints or moving components if present, and the LED illumination system.

Because the instrument incorporates an LED light, users should follow the manufacturer's instructions for cleaning and sterilization of the illumination components. Electrical or integrated lighting components must only be processed using methods approved for the specific instrument. The LED function and connections should be inspected before each use.

Proper maintenance is important for preserving the instrument's mechanical performance and illumination capability. Any visible damage, corrosion, loose component, damaged tooth, or malfunctioning LED should be evaluated before further clinical use.

With its 30 mm × 150 mm toothed blade, integrated LED illumination, and reusable design, this breast retractor is intended to support controlled tissue exposure and enhanced visibility in professional breast and plastic surgery environments.

Key Features

  • Breast retractor with integrated LED light
  • Blade dimensions: 30 mm × 150 mm
  • Toothed blade design for controlled tissue engagement
  • Reusable surgical instrument
  • Provides focused illumination of the operative field
  • Designed for controlled tissue retraction
  • Supports improved surgical visualization
  • Suitable for breast and plastic surgery procedures
  • Useful for procedures requiring stable tissue exposure
  • Compact blade dimensions for targeted retraction
  • LED function should be checked before use
  • Requires appropriate cleaning, inspection, and sterilization

Product Specifications

SpecificationDetails
Product TypeBreast Retractor
ApplicationBreast & Plastic Surgery
Blade Dimensions30 mm × 150 mm
Blade TypeToothed
IlluminationLED Light
ReusableYes
Quantity1 Piece
MaterialNot specified
Light SystemIntegrated LED
SterilizationFollow manufacturer and facility-validated protocol

FAQs

1. What is this breast retractor used for?

It is designed to provide controlled tissue retraction and surgical exposure during breast and plastic surgery procedures.

2. What is the blade size?

The blade measures 30 mm × 150 mm.

3. Does the blade have teeth?

Yes. The blade features a toothed working surface designed for controlled tissue engagement.

4. Does this breast retractor have an LED light?

Yes. It features integrated LED illumination to help provide focused lighting at the surgical site.

5. Is the breast retractor reusable?

Yes. It is specified as a reusable instrument and should be properly cleaned, inspected, and sterilized between procedures.

6. Can it be used for breast augmentation?

It may be used to assist with tissue retraction and surgical exposure during breast augmentation and other breast procedures, according to the surgeon's technique.

7. How should the toothed blade be maintained?

The teeth should be carefully cleaned and inspected after each use to ensure there is no retained surgical material, deformation, or damage.

8. How should the LED system be maintained?

Inspect the LED and associated components before use and follow the manufacturer's specific cleaning, maintenance, and sterilization instructions for the integrated lighting system.