
C-Circular Ring Breast Retractors Fiber optic insulated Blade
Direct Manufacturer Pricing • Tax Exclusive
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The C-Circular Ring Breast Retractor with Fiber Optic Insulated Blade is a specialized surgical instrument designed to assist surgeons with controlled tissue retraction and operative exposure during breast surgery and other appropriate plastic surgery procedures. Its circular ring configuration provides a stable retraction platform, while the fiber optic illumination helps direct light toward the surgical field.
The integrated fiber optic system is particularly useful when direct overhead lighting does not provide sufficient illumination to the deeper or partially obscured areas of the operative field. By positioning the light source close to the surgical site, the instrument can help improve visualization and reduce shadows during tissue manipulation. Compatibility with the appropriate fiber optic light source should be confirmed before use.
The insulated blade is designed to provide an electrically insulated working surface, which can be beneficial when the instrument is used in surgical environments involving electrosurgical equipment. The insulation should be carefully inspected before every procedure because cracks, chips, peeling, or other damage can compromise the intended insulating function.
The C-circular ring design allows controlled tissue retraction while helping maintain access to the operative area. Its configuration can support procedures where consistent exposure of breast tissue is required. The exact application depends on the surgical technique, patient anatomy, and instrument configuration selected by the qualified surgical team.
As a professional surgical instrument, proper care is essential for maintaining the retractor's mechanical, optical, and insulated components. After use, it should be cleaned according to the manufacturer's instructions, thoroughly inspected, and processed using the validated sterilization procedure appropriate for the instrument. Fiber optic connections and optical surfaces should be handled carefully to avoid damage.
The insulated blade should receive particular attention during cleaning and inspection. Abrasive cleaning methods or practices that could damage the insulation should be avoided unless specifically approved by the manufacturer. Before use, the surgical team should verify that the blade insulation and fiber optic illumination are in appropriate working condition.
The exact dimensions, blade size, fiber optic connector, ring diameter, and base material are not specified in the supplied product information and should be confirmed with the manufacturer before ordering.
Key Features
- C-circular ring breast retractor design
- Integrated fiber optic illumination
- Insulated working blade
- Designed for breast and plastic surgery
- Supports controlled tissue retraction
- Helps improve illumination of the operative field
- Provides structured surgical exposure
- Insulated blade requires careful inspection before use
- Fiber optic components require proper handling
- Suitable for professional surgical environments
- Reusable configuration when supplied as a reusable instrument
- Clean and sterilize according to manufacturer instructions
Product Specifications
| Specification | Details |
|---|---|
| Product Name | C-Circular Ring Breast Retractor |
| Instrument Type | Breast Retractor |
| Design | C-Circular Ring |
| Illumination | Fiber Optic |
| Blade Type | Insulated Blade |
| Primary Application | Breast Surgery / Plastic Surgery |
| Function | Tissue Retraction and Surgical Exposure |
| Reusable | Not specified |
| Material | Not specified |
| Blade Dimensions | Not specified |
| Ring Diameter | Not specified |
| Fiber Optic Connector | Not specified |
| Sterilization | Follow manufacturer and facility-validated protocols |
FAQs
1. What is a C-Circular Ring Breast Retractor?
It is a specialized retractor designed to provide controlled tissue retraction and surgical exposure during breast and appropriate plastic surgery procedures.
2. What is the purpose of the fiber optic illumination?
Fiber optic illumination directs focused light toward the operative field, helping improve visualization during procedures where additional localized lighting is required.
3. What is an insulated blade?
An insulated blade has an insulating layer over the designated working surface. It is designed for use in surgical environments where electrical insulation may be required.
4. Why should the insulated blade be inspected?
The insulation should be checked before use for cracks, chips, peeling, or other damage. Damaged insulation may compromise the intended electrical insulation properties.
5. Can this retractor be used for breast augmentation?
It may be suitable for surgical exposure during breast augmentation or other breast procedures depending on the surgeon's technique and the specific instrument configuration.
6. Does the retractor require a special light source?
The fiber optic system requires a compatible light source and connector. The exact connector specification should be confirmed before purchase.
7. How should the retractor be cleaned?
Clean and process the instrument according to the manufacturer's instructions. Particular care should be taken around the fiber optic components and insulated blade.
8. Is this retractor reusable?
The supplied title does not specify whether this particular version is reusable. Reusability should be confirmed from the manufacturer's instructions before clinical use.
