
Chandran Anterior Retractor for THR with Strikeplate
Direct Manufacturer Pricing • Tax Exclusive
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The Chandran Anterior Retractor for THR with Strikeplate is a specialized orthopedic surgical instrument designed to support anterior hip exposure during total hip replacement (THR) procedures. It combines a dedicated anterior retractor configuration with a strikeplate intended to facilitate controlled handling during placement and positioning.
Anterior hip replacement requires appropriate exposure of the operative field while maintaining controlled positioning of surrounding soft tissues. A dedicated anterior retractor can help maintain access to the hip joint and provide the surgeon with a clear working area during critical stages of the procedure.
The Chandran retractor is designed for use during anterior hip exposure and soft tissue retraction. Its strikeplate provides a designated surface for controlled application of force when positioning the instrument, according to the surgical technique and instrument design. This feature can be useful when the retractor needs to be seated or positioned within the operative field.
The instrument may be used during total hip replacement alongside other anterior approach instruments, including femoral elevators, Hohmann retractors, acetabular retractors, femoral preparation instruments, femoral stem impactors, and other specialized hip surgery tools. The combination of instruments used depends on the surgeon's preferred approach and the requirements of the individual procedure.
The strikeplate is an important design feature of this configuration. It provides a defined area for instrument manipulation while helping maintain controlled positioning of the retractor. The surgeon should use the instrument only in accordance with the intended technique and applicable manufacturer instructions.
The Chandran Anterior Retractor for THR with Strikeplate is intended for professional orthopedic surgical environments. Before use, the instrument should be inspected for structural integrity, proper alignment, surface condition, and any signs of damage or excessive wear. Instruments that do not meet applicable inspection criteria should be removed from service.
If supplied as a reusable surgical instrument, the retractor should be cleaned, decontaminated, inspected, packaged, and sterilized according to the manufacturer's validated instructions. Appropriate processing procedures should also follow the healthcare facility's applicable infection-control requirements.
The Chandran Anterior Retractor for THR with Strikeplate provides a dedicated option for controlled anterior hip exposure during total hip replacement. Its retractor design and strikeplate configuration make it suitable for surgical teams requiring specialized instrumentation for anterior orthopedic hip procedures.
Key Features
- Designed for total hip replacement procedures
- Supports anterior hip surgical exposure
- Provides controlled soft tissue retraction
- Includes an integrated strikeplate
- Supports controlled instrument positioning
- Designed for anterior orthopedic hip procedures
- Can complement specialized THR instrument sets
- Suitable for use with other anterior hip retractors
- Supports access to the operative field
- Intended for professional orthopedic surgical use
- Reusable when supplied as a reusable instrument
- Designed for controlled surgical handling
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Chandran Anterior Retractor for THR with Strikeplate |
| Instrument Type | Anterior Hip Retractor |
| Surgical Specialty | Orthopedic Surgery |
| Primary Application | Total Hip Replacement |
| Surgical Approach | Anterior Hip Approach |
| Primary Function | Soft Tissue Retraction and Surgical Exposure |
| Additional Feature | Strikeplate |
| Working Area | Anterior Hip / Hip Joint |
| Implant Function | Not an implant component |
| Reusable | Depending on supplied configuration |
| Sterilization | Follow validated manufacturer instructions |
FAQs
What is the Chandran Anterior Retractor for THR with Strikeplate?
It is an orthopedic surgical retractor designed to assist with anterior hip exposure and soft tissue retraction during total hip replacement procedures, with an integrated strikeplate for controlled handling.
What is the strikeplate used for?
The strikeplate provides a designated surface for controlled application of force when positioning the retractor, according to the intended surgical technique and manufacturer instructions.
What does THR mean?
THR stands for Total Hip Replacement, a surgical procedure used to replace damaged components of the hip joint with prosthetic components.
Can this retractor be used during anterior total hip arthroplasty?
It is designed to support anterior hip exposure during total hip replacement procedures. Its use should follow the surgeon's preferred technique and applicable instrument instructions.
What other instruments can be used with the Chandran retractor?
It can complement femoral elevators, Hohmann retractors, acetabular retractors, femoral preparation instruments, femoral stem impactors, and other anterior hip surgical instruments.
Is the Chandran Anterior Retractor reusable?
If supplied as a reusable instrument, it should be cleaned, inspected, sterilized, and maintained according to the manufacturer's validated instructions.
How should the retractor be sterilized?
Cleaning, inspection, packaging, and sterilization should follow the manufacturer's validated processing instructions and applicable healthcare facility protocols.
