CleanWave Kerrison, 3mm, 40 deg up, Panther
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-50694
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
NeurosurgicalSKU: SP-50694AISI 420 Martensitic

3mm CleanWave Kerrison 40° Up Panther

4.9 / 5.0•18 Verified OR Evaluations
$1045.00$1245.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $200.00 (16% OFF)
  • 3mm CleanWave Kerrison 40° Up Panther designed with a 40° Up configuration for controlled bone removal.
  • 3mm cutting tip provides a defined cutting profile for neurosurgical procedures.
  • Ergonomic design supports a specialized working orientation within the operative field.
  • Suitable for neurosurgical and spinal applications requiring a Kerrison instrument.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 3mm CleanWave Kerrison 40° Up Panther is a specialized neurosurgical instrument designed for controlled bone removal in spinal and neurosurgical procedures. Its 3mm cutting tip provides a distinct working orientation that can assist with positioning the cutting end within the operative field.

With an overall length of and a 3mm cutting tip, this Kerrison provides a defined cutting profile for neurosurgical applications. The ergonomic Panther handle allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • for controlled manual handling.
  • 3mm cutting tip provides a defined cutting profile.
  • Ergonomic design for specialized working orientation.
  • Designed for controlled bone removal.
  • Suitable for neurosurgical applications.
  • Supports positioning of the working end within the operative field.
  • Specialized CleanWave pattern for professional neurosurgical instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeCleanWave Kerrison
Overall Length
Working End / Blade / Jaw3mm cutting tip
Configuration40° Up
Primary FunctionBone Removal
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeNeurosurgical

The 3mm CleanWave Kerrison 40° Up Panther combines a overall length with a 3mm cutting tip and 40° Up configuration.
Its defined working profile is intended for controlled bone removal in neurosurgical applications.

Design & Function

The CleanWave Kerrison features a 40° Up working configuration designed to provide a specialized orientation during spinal procedures. The cutting tip can assist in positioning the working end according to the requirements of the operative field.

The 3mm cutting tip provides a defined cutting profile, while the overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a Kerrison instrument.

Surgical Applications

The 3mm CleanWave Kerrison 40° Up Panther may be used for neurosurgical and spinal applications involving controlled bone removal. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the CleanWave Kerrison before use, paying particular attention to the cutting tip, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the CleanWave Kerrison appropriately to protect its cutting tip and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this CleanWave Kerrison?
The overall length is .

2. What is the working end / blade or tip design of the instrument?
It features 3mm cutting tip.

3. Is this CleanWave Kerrison curved or straight?
It features a 40° Up configuration.

4. What is a CleanWave Kerrison used for?
It is designed for controlled bone removal in neurosurgical applications.

5. What clinical advantage does the ergonomic design provide?
The ergonomic design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and spinal applications where a 40° Up CleanWave Kerrison is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the CleanWave Kerrison be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.