
5mm CleanWave Kerrison 40° Up
Direct Manufacturer Pricing • Tax Exclusive
- 5mm CleanWave Kerrison 40° Up designed with a upward configuration for robust bone removal.
- 5 mm working width provides a defined cutting profile for neurosurgical procedures.
- Upward design supports a specialized working orientation within the operative field.
- Suitable for neurosurgical and orthopedic applications requiring a upward angulated Kerrison.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 5mm CleanWave Kerrison 40° Up is a specialized neurosurgical instrument designed for robust bone removal in spinal, neurosurgical, and orthopedic operations. Its 5mm tip offers increased cutting capacity while maintaining precise control, making it ideal for both routine and complex surgical tasks.
With an overall length of and a 5mm working width, this Kerrison provides a defined cutting profile for neurosurgical applications. The 40° upward angulation allows better visualization and access to the surgical site, ensuring accuracy in confined operative spaces.
Key Features
- for controlled manual handling.
- 5 mm working width provides a defined cutting profile.
- 40° upward angulation for specialized working orientation.
- Designed for robust bone removal and precision cutting.
- Suitable for neurosurgical and orthopedic applications.
- Supports positioning of the working end within the operative field.
- Specialized CleanWave pattern for professional neurosurgical instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | CleanWave Kerrison |
| Overall Length | |
| Working End / Blade / Jaw | 5 mm |
| Configuration | Upward Angled |
| Primary Function | Bone Removal |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Neurosurgical / Orthopedic |
The 5mm CleanWave Kerrison 40° Up combines a overall length with a 5 mm working width and upward angulation.
Its defined working profile is intended for robust bone removal in neurosurgical applications.
Design & Function
The CleanWave Kerrison features a 40° upward angulation designed to provide a specialized orientation during bone removal procedures. The working end design can assist in positioning the cutting end according to the requirements of the operative field.
The 5 mm working width provides a defined cutting profile, while the allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a Kerrison instrument.
Surgical Applications
The 5mm CleanWave Kerrison 40° Up may be used for neurosurgical and orthopedic applications involving robust bone removal. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the CleanWave Kerrison before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the CleanWave Kerrison appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this CleanWave Kerrison?
The overall length is .
2. What is the working end / blade or tip design of the instrument?
It features 5 mm working width.
3. Is this CleanWave Kerrison curved or straight?
It features a 40° upward angulation.
4. What is a CleanWave Kerrison used for?
It is designed for controlled bone removal in neurosurgical applications.
5. What clinical advantage does the upward angulation provide?
The upward angulation provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and orthopedic applications where a 40° upward angulated Kerrison is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the CleanWave Kerrison be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
