Cloward Style Double Hinge Retractor – Handle Only, 9 1/4″
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-46769
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
NeurosurgicalSKU: SP-46769AISI 420 Martensitic

9 1/4″ Cloward Double Hinge Retractor Handle Only

4.9 / 5.0•18 Verified OR Evaluations
$432.00$445.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $13.00 (3% OFF)
  • 9 1/4″ Cloward Double Hinge Retractor Handle Only designed with a double hinge configuration for stable tissue retraction.
  • Handle Only provides a defined retraction profile for neurosurgical procedures.
  • Ergonomic design supports a specialized working orientation within the operative field.
  • Suitable for neurosurgical and spinal applications requiring a reliable retraction instrument.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 9 1/4″ Cloward Double Hinge Retractor Handle Only is a specialized neurosurgical instrument designed for stable and adjustable tissue retraction during spinal and neurosurgical procedures. Its double hinge mechanism provides precise adjustment of blade tension and spacing, allowing optimal exposure within the operative field.

With an overall length of 9 1/4 inches, this handle is constructed from high-quality surgical stainless steel, ensuring durability and corrosion resistance. The design allows for seamless integration with Cloward blade attachments, supporting controlled manual manipulation during surgical interventions.

Key Features

  • 9 1/4-inch overall length for enhanced handling and maneuverability.
  • Double hinge mechanism allows for precise adjustment of blade tension and spacing.
  • Ergonomic design supports a specialized working orientation within the operative field.
  • Designed for stable tissue retraction during spinal and neurosurgical procedures.
  • Suitable for neurosurgical applications requiring reliable retraction.
  • Supports positioning of the working end for optimal exposure.
  • Specialized Cloward pattern for professional neurosurgical instrument sets.
  • Corrosion-resistant surgical-grade stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeCloward Double Hinge Retractor
Overall Length9 1/4″
Working End / Blade / JawHandle Only
ConfigurationDouble Hinge
Primary FunctionTissue Retraction
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeNeurosurgical

The 9 1/4″ Cloward Double Hinge Retractor Handle Only combines a 9 1/4-inch overall length with a handle-only design and double hinge configuration.
Its defined working profile is intended for stable tissue retraction in neurosurgical applications.

Design & Function

The Cloward Double Hinge Retractor features a double hinge working configuration designed to provide a specialized orientation during spinal procedures. The handle design can assist in positioning the working end according to the requirements of the operative field.

The handle profile provides a defined retraction profile, while the 9 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a reliable retraction instrument.

Surgical Applications

The 9 1/4″ Cloward Double Hinge Retractor Handle Only may be used for neurosurgical and spinal applications involving stable tissue retraction. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Cloward Double Hinge Retractor before use, paying particular attention to the handle and hinge mechanism. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Cloward Double Hinge Retractor appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Cloward Double Hinge Retractor?
The overall length is 9 1/4 inches.

2. What is the working end / blade or tip design of the instrument?
It features Handle Only.

3. Is this Cloward Double Hinge Retractor curved or straight?
It features a double hinge configuration.

4. What is a Cloward Double Hinge Retractor used for?
It is designed for controlled tissue retraction in neurosurgical applications.

5. What clinical advantage does the double hinge design provide?
The double hinge provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and spinal applications where a reliable retraction instrument is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the functional geometry of the instrument.

8. How should the Cloward Double Hinge Retractor be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.