Cooley Vascular Clamp 90° Angled, Large Jaw
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-34021
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
CVTSKU: SP-34021AISI 420 Martensitic

Cooley Vascular Clamp 90° Angled Large Jaw

4.9 / 5.0•18 Verified OR Evaluations
$100.00$120.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (17% OFF)
  • Cooley Vascular Clamp 90° Angled Large Jaw designed with an angled configuration for controlled clamping of vascular structures.
  • Large jaw size provides a defined clamping profile for cardiovascular procedures.
  • Angled design supports a specialized working orientation within the operative field.
  • Suitable for cardiovascular and vascular surgery applications requiring an angled vascular clamp.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Cooley Vascular Clamp 90° Angled Large Jaw is a specialized cardiovascular instrument designed for controlled clamping of vascular structures during professional vascular and cardiovascular procedures. Its 90° angled jaw configuration provides a distinct working orientation that can assist with positioning the large jaws within the operative field.

With an overall length of and a large jaw size, this vascular clamp provides a defined clamping profile for cardiovascular applications. The angled design allows the working end to approach vascular structures from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • for controlled manual handling.
  • provides a defined clamping profile.
  • Angled configuration for specialized working orientation.
  • Designed for controlled clamping of vascular structures.
  • Suitable for cardiovascular and vascular surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Cooley pattern for professional cardiovascular instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeCooley Vascular Clamp
Overall Length
Working End / Blade / Jaw
ConfigurationAngled
Primary FunctionControlled Clamping of Vascular Structures
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeCardiovascular / Vascular Surgery

The Cooley Vascular Clamp 90° Angled Large Jaw combines a overall length with a large jaw size and angled configuration.
Its defined working profile is intended for controlled clamping of vascular structures in cardiovascular applications.

Design & Function

The Cooley Vascular Clamp features an angled working configuration designed to provide a specialized orientation during vascular procedures. The large jaw design can assist in positioning the working end according to the requirements of the operative field.

The large jaw profile provides a defined clamping profile, while the allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring an angled vascular clamp.

Surgical Applications

The Cooley Vascular Clamp 90° Angled Large Jaw may be used for cardiovascular and vascular surgery applications involving controlled clamping of vascular structures. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Cooley Vascular Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Cooley Vascular Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Cooley Vascular Clamp?
The overall length is .

2. What is the working end / jaw design of the instrument?
It features .

3. Is this Cooley Vascular Clamp angled or straight?
It features an angled configuration.

4. What is a Cooley Vascular Clamp used for?
It is designed for controlled clamping of vascular structures in cardiovascular applications.

5. What clinical advantage does the angled design provide?
The angled design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and vascular surgery applications where an angled large jaw clamp is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Cooley Vascular Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.