DeBakey Castaneda Clamp 1.4mm Slightly Curved Jaw, Curved Handle
Direct Manufacturer Pricing • Tax Exclusive
The DeBakey Castaneda Clamp features 1.4 mm slightly curved jaws and a curved handle designed to support controlled access and handling during delicate vascular procedures. Its specialized configuration makes it suitable for selected cardiovascular and vascular surgical applications requiring precision instrument positioning.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The DeBakey Castaneda Clamp 1.4mm Slightly Curved Jaw, Curved Handle is a specialized vascular surgical instrument designed for procedures that require controlled clamping and access to delicate vascular structures. Its narrow jaw profile and curved handle configuration support precise instrument placement in selected cardiovascular and reconstructive surgical applications.
Applications in Vascular Surgery
Vascular clamps are used to control blood flow temporarily during selected surgical procedures. Depending on the specific design and intended use, a DeBakey Castaneda Clamp may be appropriate for delicate vessel handling, vascular repair, and procedures involving small or anatomically restricted operative sites.
The suitability of this instrument depends on the target vessel, the surgical approach, and the manufacturer's intended application. The clamp should be selected by qualified healthcare professionals according to the requirements of the procedure.
Slightly Curved Jaw Design
The slightly curved jaw design supports access to vascular structures where a straight jaw may be less convenient. The specified 1.4 mm jaw dimension provides an important reference for identifying the instrument, although the exact measurement should be confirmed as jaw width, opening, or another dimension according to the manufacturer's specifications.
A narrow jaw profile can support positioning in confined surgical spaces. Proper jaw alignment and controlled application are essential when working with delicate tissues. The instrument should not be used beyond its intended clamping function or applied with excessive force.
Curved Handle for Instrument Control
The curved handle is designed to provide an alternative approach angle during instrument positioning. Depending on the surgical site and surrounding anatomy, this configuration may improve access and maneuverability compared with a straight-handled instrument.
Handle geometry influences the operator's grip, visibility, and working clearance. The precise curvature, overall length, and mechanism of this DeBakey Castaneda Clamp should be verified with the supplier before purchase.
Material and Construction
Vascular clamps are commonly manufactured from surgical-grade stainless steel, selected for its strength, corrosion resistance, and suitability for repeated reprocessing when designed as a reusable instrument. However, the exact material grade and surface finish of this model should be confirmed with the manufacturer.
Reliable construction is important for maintaining jaw alignment and consistent mechanical performance. Before use, the clamp should be inspected for corrosion, deformation, damaged jaw surfaces, and any restriction in its operating mechanism.
Benefits for Surgical Instrument Inventory
The DeBakey Castaneda Clamp offers a specialized jaw and handle configuration for facilities that perform vascular and cardiovascular procedures. Its defined 1.4 mm jaw specification and slightly curved profile help purchasing teams distinguish it from other vascular clamps with different dimensions or geometries.
For hospitals, specialist surgical centers, and medical instrument distributors, verifying the overall length, jaw measurements, material, and operating mechanism helps ensure the instrument matches the intended clinical requirements.
Cleaning, Sterilization, and Maintenance
If supplied as a reusable instrument, the DeBakey Castaneda Clamp must be cleaned, inspected, and sterilized according to the manufacturer's validated instructions. Thorough cleaning is necessary before sterilization to remove blood, tissue, and other organic residues from the jaws and mechanical components.
Following cleaning, inspect the instrument for corrosion, jaw misalignment, surface damage, and mechanical wear. Use only sterilization methods compatible with the instrument's material and manufacturer instructions. Proper storage and routine inspection help maintain instrument condition and support its intended service life.
Key Features
Specialized DeBakey Castaneda vascular surgical clamp.
Slightly curved jaw profile for selected vascular applications.
Specified 1.4 mm jaw dimension; exact measurement type should be verified.
Curved handle design for alternative instrument positioning.
Intended for controlled clamping in appropriate surgical procedures.
Suitable for selected vascular and cardiovascular applications.
Narrow jaw configuration for access to restricted operative areas.
Surgical-grade stainless steel construction is common; confirm the exact material grade.
Requires inspection of jaw alignment and mechanical function before use.
Reprocessing must follow the manufacturer's validated instructions.
Intended for use by qualified healthcare professionals.
Product Specifications
| Specification | Details |
|---|---|
| Product Name | DeBakey Castaneda Clamp |
| Instrument Category | Vascular Surgical Clamp |
| Surgical Specialty | Vascular and Cardiovascular Surgery |
| Jaw Dimension | 1.4 mm, measurement type to be confirmed |
| Jaw Shape | Slightly Curved |
| Handle Design | Curved Handle |
| Primary Function | Vascular Clamping |
| Overall Length | Confirm with Supplier |
| Operating Mechanism | Confirm with Supplier |
| Material | Confirm exact grade with Supplier |
| Surface Finish | Manufacturer-Specific |
| Reusable Status | Confirm Product Labeling |
| Sterilization Compatibility | Follow Manufacturer's Instructions |
| Intended Users | Qualified Healthcare Professionals |
Frequently Asked Questions
1. What is a DeBakey Castaneda Clamp used for?
A DeBakey Castaneda Clamp is a specialized vascular instrument intended for clamping applications in selected vascular and cardiovascular procedures. Its precise use depends on the model's design and the manufacturer's intended application.
2. What does the 1.4 mm specification mean?
The product title identifies a 1.4 mm dimension, but it does not clarify whether this refers to jaw width, opening, or another measurement. Confirm the exact dimension with the supplier before ordering.
3. What is the advantage of slightly curved jaws?
Slightly curved jaws can help the operator approach selected anatomical structures at an appropriate angle. Their suitability depends on the surgical site, vessel anatomy, and intended clamping technique.
4. Why does this clamp have a curved handle?
A curved handle provides an alternative approach angle and may improve access or working clearance in selected surgical settings. The specific ergonomic advantages depend on the handle geometry and procedure.
5. What material is used to manufacture this vascular clamp?
Surgical vascular clamps are commonly made from stainless steel or other specified medical-grade materials. The exact composition of this DeBakey Castaneda Clamp should be confirmed with the manufacturer.
6. Is the DeBakey Castaneda Clamp reusable?
Reusability depends on the product labeling and manufacturer's instructions. Reusable instruments must be cleaned, inspected, and sterilized according to validated procedures before clinical reuse.
7. What should buyers verify before purchasing this clamp?
Verify the 1.4 mm measurement, overall length, jaw configuration, handle curvature, material grade, operating mechanism, and sterilization requirements to ensure the instrument meets the intended clinical needs.