DeBakey Grasper 1×2 AG Angled Left Small Jaw
Direct Manufacturer Pricing • Tax Exclusive
- DeBakey Grasper 1×2 AG Angled Left Small Jaw designed with an angled-left configuration for controlled grasping and manipulation of tissue.
- 1×2 AG jaw dimension provides a defined grasping profile for cardiovascular procedures.
- Angled-left design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and thoracic surgery applications requiring a specialized grasper.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The DeBakey Grasper 1×2 AG Angled Left Small Jaw is a specialized cardiovascular instrument designed for controlled grasping and manipulation of tissue within the operative field. Its angled-left small jaw configuration provides a distinct working orientation that can assist with positioning the grasping end within the operative field.
With an overall length of and a 1×2 AG jaw dimension, this grasper provides a defined grasping profile for cardiovascular applications. The angled-left design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- for controlled manual handling.
- 1×2 AG jaw dimension provides a defined grasping profile.
- Angled-left configuration for specialized working orientation.
- Designed for controlled grasping and manipulation of tissue.
- Suitable for cardiovascular applications.
- Supports positioning of the working end within the operative field.
- Specialized DeBakey pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | DeBakey Grasper |
| Overall Length | |
| Working End / Blade / Jaw | 1×2 AG |
| Configuration | Angled Left |
| Primary Function | Grasping and Manipulation |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular |
The DeBakey Grasper 1×2 AG Angled Left Small Jaw combines a overall length with a 1×2 AG jaw dimension and angled-left configuration.
Its defined working profile is intended for controlled grasping and manipulation of tissue in cardiovascular applications.
Design & Function
The DeBakey Grasper features an angled-left working configuration designed to provide a specialized orientation during tissue manipulation. The jaw design can assist in positioning the working end according to the requirements of the operative field.
The 1×2 AG jaw profile provides a defined grasping profile, while the allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a specialized grasper.
Surgical Applications
The DeBakey Grasper 1×2 AG Angled Left Small Jaw may be used for cardiovascular and thoracic surgery applications involving tissue grasping and manipulation. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the DeBakey Grasper before use, paying particular attention to the working end, jaw alignment, and grasping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the DeBakey Grasper appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this DeBakey Grasper?
The overall length is .
2. What is the working end / blade or tip design of the instrument?
It features 1×2 AG jaw configuration.
3. Is this DeBakey Grasper curved or straight?
It features an angled-left configuration.
4. What is a DeBakey Grasper used for?
It is designed for controlled grasping and manipulation of tissue in cardiovascular applications.
5. What clinical advantage does the angled-left design provide?
The angled-left design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and thoracic surgery applications where a specialized grasper is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the DeBakey Grasper be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.