11″ DeBakey Tangential Occlusion Clamp 7.5cm Long, 1.7cm Deep
Direct Manufacturer Pricing • Tax Exclusive
- 11″ DeBakey Tangential Occlusion Clamp designed with a tangential configuration for partial vessel occlusion.
- 7.5 cm jaw length and 1.7 cm depth provide a defined clamping profile for cardiovascular procedures.
- Tangential design supports a specialized working orientation within the operative field.
- Suitable for cardiovascular and arterial repair applications requiring a tangential clamp.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 11″ DeBakey Tangential Occlusion Clamp is a specialized cardiovascular instrument designed for partial vessel occlusion during arterial repair and cardiovascular surgery. Its tangential design allows surgeons to clamp vessels without completely interrupting blood flow.
Featuring jaws measuring 11 inches in overall length, with a jaw length of 7.5 cm and a depth of 1.7 cm, this clamp provides excellent exposure and control during complex vascular procedures. The premium stainless steel construction ensures durability and reliability in the operating room.
Key Features
- 11-inch overall length for optimal reach and handling.
- 7.5 cm jaw length and 1.7 cm depth provide a defined clamping profile.
- Tangential configuration for specialized working orientation.
- Designed for partial vessel occlusion during arterial repair.
- Suitable for cardiovascular surgery applications.
- Supports positioning of the clamp within the operative field.
- Specialized DeBakey pattern for professional cardiovascular instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | DeBakey Tangential Occlusion Clamp |
| Overall Length | 11″ |
| Working End / Blade / Jaw | 7.5 cm jaw length and 1.7 cm depth |
| Configuration | Tangential |
| Primary Function | Partial Vessel Occlusion |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Cardiovascular Surgery |
The 11″ DeBakey Tangential Occlusion Clamp combines an 11-inch overall length with a 7.5 cm jaw length and 1.7 cm depth. Its defined working profile is intended for partial vessel occlusion in cardiovascular applications.
Design & Function
The DeBakey Tangential Occlusion Clamp features a tangential working configuration designed to provide a specialized orientation during arterial repair. The jaw design can assist in positioning the clamp according to the requirements of the operative field.
The jaw dimensions provide a defined clamping profile, while the 11-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for cardiovascular procedures requiring a tangential clamp.
Surgical Applications
The 11″ DeBakey Tangential Occlusion Clamp may be used for cardiovascular and arterial repair applications involving partial vessel occlusion. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the DeBakey Tangential Occlusion Clamp before use, paying particular attention to the working end, jaw alignment, and clamping edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the DeBakey Tangential Occlusion Clamp appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Clamp?
The overall length is 11 inches.
2. What is the working end / blade or tip design of the instrument?
It features 7.5 cm jaw length and 1.7 cm depth.
3. Is this Clamp curved or straight?
It features a tangential configuration.
4. What is a DeBakey Tangential Occlusion Clamp used for?
It is designed for controlled partial vessel occlusion in cardiovascular applications.
5. What clinical advantage does the tangential design provide?
The tangential design provides a specialized working orientation for positioning the clamp within the operative field.
6. Is this instrument suitable for cardiovascular surgery?
It may be used in cardiovascular and arterial repair applications where a tangential clamp is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the DeBakey Tangential Occlusion Clamp be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.