12 1/2″ Demel Wire Guide 57mm Diameter
Direct Manufacturer Pricing • Tax Exclusive
- 12 1/2″ Demel Wire Guide designed with a standard configuration for controlled wire guidance.
- 57 mm diameter provides a defined guiding profile for neurosurgical procedures.
- Standard design supports a specialized working orientation within the operative field.
- Suitable for neurosurgical applications requiring a wire guide.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 12 1/2″ Demel Wire Guide is a specialized neurosurgical instrument designed for controlled guidance and positioning of wire during appropriate surgical procedures. Its 57 mm diameter provides a distinct working orientation that can assist with positioning the wire within the operative field.
With an overall length of 12 1/2 inches and a 57 mm diameter, this wire guide provides a defined profile for neurosurgical applications. The design allows the working end to approach anatomical targets from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 12 1/2-inch overall length for controlled manual handling.
- 57 mm diameter provides a defined guiding profile.
- Specialized configuration for precise wire positioning.
- Designed for controlled guidance during neurosurgical procedures.
- Suitable for neurosurgical applications requiring a wire guide.
- Supports positioning of the wire within the operative field.
- Specialized Demel pattern for professional neurosurgical instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Demel Wire Guide |
| Overall Length | 12 1/2″ |
| Working End / Blade / Jaw | 57 mm diameter |
| Configuration | Standard |
| Primary Function | Wire Guidance |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Neurosurgical |
The 12 1/2″ Demel Wire Guide combines a 12 1/2-inch overall length with a 57 mm diameter. Its defined guiding profile is intended for controlled wire positioning in neurosurgical applications.
Design & Function
The Demel Wire Guide features a standard working configuration designed to provide a specialized orientation during wire placement. The diameter can assist in positioning the wire according to the requirements of the operative field.
The 57 mm diameter provides a defined guiding profile, while the 12 1/2-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a wire guide.
Surgical Applications
The 12 1/2″ Demel Wire Guide may be used for neurosurgical applications involving wire guidance and positioning. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the wire guide before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the wire guide appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Wire Guide?
The overall length is 12 1/2 inches.
2. What is the working end / diameter of the instrument?
It features a 57 mm diameter.
3. Is this Wire Guide curved or straight?
It features a standard configuration.
4. What is a Wire Guide used for?
It is designed for controlled wire guidance in neurosurgical applications.
5. What clinical advantage does the diameter provide?
The diameter provides a specialized working orientation for positioning the wire within the operative field.
6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical applications where a wire guide is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Wire Guide be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.