118mm Dilator Titanium 24.9mm Diameter
Direct Manufacturer Pricing • Tax Exclusive
- 118mm Dilator Titanium 24.9mm Diameter designed with a straight configuration for sequential dilation.
- 24.9mm diameter provides a defined dilation profile for spinal procedures.
- Straight design supports a specialized working orientation within the operative field.
- Suitable for spinal and minimally invasive surgery applications requiring a straight dilator.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 118mm Dilator Titanium 24.9mm Diameter is a specialized spinal instrument designed for advanced-stage sequential dilation in minimally invasive procedures. Its 24.9mm diameter establishes a large working corridor suitable for wide retractors or multi-instrument access, allowing controlled expansion of soft tissue and optimized surgical exposure.
With an overall length of 118mm and a 24.9mm diameter, this dilator provides precise alignment with guidewires and previously inserted dilators. The smooth, tapered design allows for gentle tissue dilation, supporting controlled manual manipulation during procedures.
Key Features
- 118mm overall length for optimal depth in surgical procedures.
- 24.9mm diameter provides a defined dilation profile.
- Smooth tapered design for gentle tissue dilation.
- Designed for advanced-stage sequential dilation.
- Suitable for minimally invasive spinal surgery applications.
- Supports positioning of the working end within the operative field.
- Corrosion-resistant surgical-grade titanium construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Dilator |
| Overall Length | 118mm |
| Working End / Blade / Jaw | 24.9mm Diameter |
| Configuration | Straight |
| Primary Function | Sequential Dilation |
| Material | Titanium |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Spinal Surgery |
The 118mm Dilator Titanium 24.9mm Diameter combines a 118mm overall length with a 24.9mm diameter.
Its defined working profile is intended for sequential dilation in spinal applications.
Design & Function
The Dilator features a straight working configuration designed to provide a specialized orientation during spinal procedures. The smooth tapered design can assist in positioning the working end according to the requirements of the operative field.
The 24.9mm diameter provides a defined dilation profile, while the 118mm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for spinal procedures requiring a dilator.
Surgical Applications
The 118mm Dilator Titanium 24.9mm Diameter may be used for spinal and minimally invasive surgery applications involving sequential dilation of soft tissue. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the dilator before use, paying particular attention to the working end and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the dilator appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Dilator?
The overall length is 118mm.
2. What is the working end / blade or tip design of the instrument?
It features 24.9mm diameter.
3. Is this Dilator curved or straight?
It features a Straight configuration.
4. What is a Dilator used for?
It is designed for controlled sequential dilation in spinal applications.
5. What clinical advantage does the smooth tapered design provide?
The design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for spinal surgery?
It may be used in spinal and minimally invasive applications where a straight dilator is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Dilator be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.