Dorsal Locking Dist Radius Variable Angle Straight plates.png
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-109895
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
Orthopedic ImplantsSKU: SP-109895AISI 420 Martensitic

Dorsal Locking Distal Radius Variable Angle Straight Plates with Screws

4.9 / 5.0•18 Verified OR Evaluations
$540.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

Dorsal Locking Distal Radius Variable Angle Straight Plates with Screws

4 sets

1 set includes 42 pcs

Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Dorsal Locking Distal Radius Variable Angle Straight Plate with Screws is a specialized orthopedic fixation system designed for distal radius fracture stabilization and reconstruction. The system combines a low-profile dorsal plate with compatible locking screws to provide controlled fixation of fractured bone fragments.

The straight plate configuration is designed for dorsal placement on the distal radius when indicated by the fracture pattern and surgical approach. Its plate geometry is intended to provide stable fixation while accommodating the anatomical requirements of the distal radius.

A key feature of this system is variable-angle locking technology. Unlike conventional fixed-angle locking plates, variable-angle systems allow compatible locking screws to be inserted within a defined angular range. This gives the surgeon greater flexibility when targeting specific fracture fragments or optimizing screw trajectories.

The included locking screws engage with the plate's threaded or variable-angle locking holes to create a stable plate-screw construct. Appropriate screw length and trajectory should be selected based on patient anatomy, fracture characteristics, and the manufacturer's surgical technique.

These plates may be used for distal radius fractures, intra-articular fractures, comminuted fractures, and other fracture patterns where dorsal plate fixation is clinically indicated. Exact indications depend on the specific implant system and manufacturer's instructions for use.

The plates are generally manufactured from implant-grade stainless steel or titanium alloy, depending on the product specification. The screws are made from compatible implant-grade material to provide mechanical stability and appropriate system compatibility.

The system is intended for use with compatible surgical instrumentation, which may include drill guides, drill bits, depth gauges, screwdrivers, and other specialized tools. Proper surgical technique and fluoroscopic assessment are essential during implant placement.

Because these are implantable orthopedic devices, they should only be selected and implanted by appropriately trained orthopedic professionals. The exact plate dimensions, hole configuration, screw sizes, material, and regulatory specifications should be confirmed with the manufacturer before clinical use.

Key Features

  • Dorsal distal radius fixation system
  • Straight plate configuration
  • Variable-angle locking technology
  • Compatible locking screws included
  • Designed for distal radius fracture stabilization
  • Allows adjustable screw trajectory within the approved angular range
  • Supports fixation of selected fracture fragments
  • Implant-grade construction
  • Designed for use with compatible instrumentation

Product Specifications

Specification Details
Product Name Dorsal Locking Distal Radius Variable Angle Straight Plate
Category Orthopedic Trauma Implants
Plate Type Dorsal / Straight
Locking Technology Variable Angle
Application Distal Radius Fracture Fixation
Screws Compatible Locking Screws Included*
Material Implant-Grade Stainless Steel / Titanium Alloy*
Plate Size Manufacturer-Specific*
Screw Diameter Manufacturer-Specific*
Screw Lengths Multiple Options*
Sterility Verify Manufacturer Packaging

*Exact dimensions, screw quantity, material, and configuration depend on the specific implant system.

Applications

  • Distal radius fracture fixation
  • Dorsal fracture stabilization
  • Comminuted distal radius fractures
  • Selected intra-articular fractures
  • Fracture fragment fixation
  • Orthopedic trauma surgery
  • Reconstructive fracture procedures

Benefits

  • Variable-angle locking: Provides flexibility for screw trajectory within the system's approved range.
  • Dorsal placement: Designed for fracture patterns requiring dorsal fixation.
  • Straight plate design: Provides a defined plate profile for appropriate distal radius anatomy.
  • Locking screw fixation: Creates a stable plate-screw construct.
  • Complete system: Plate and compatible screws can simplify implant selection and surgical preparation.

FAQs

1. What are dorsal distal radius plates used for?
They are used to stabilize and fix selected fractures of the distal radius using a plate-and-screw construct.

2. What does variable-angle locking mean?
It allows compatible locking screws to be inserted at different approved angles rather than requiring one fixed screw trajectory.

3. Are screws included with the plates?
This product title specifies plates with screws, but the exact screw quantity and sizes should be confirmed from the individual product configuration.

4. What fractures can this system treat?
It may be indicated for selected distal radius fractures, including certain comminuted and intra-articular fracture patterns, depending on the specific implant system.

5. Are these implants reusable?
No. Orthopedic fixation plates and screws are generally single-use implantable medical devices.

6. Are they supplied sterile?
Sterility depends on the specific manufacturer and packaging. Always verify the implant's labeling and instructions for use before clinical application.