Double Ended K Wire Bender 1.7mm & 2.5mm 4 Pcs
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-27280
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
General Surgery InstrumentsSKU: SP-27280AISI 420 Martensitic

Double Ended K Wire Bender 1.7mm & 2.5mm 4 Pcs

4.9 / 5.0•18 Verified OR Evaluations
$230.00$250.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $20.00 (8% OFF)

The Double Ended K-Wire Bender is an orthopedic instrument designed to assist with bending compatible Kirschner wires during selected surgical procedures. Its double-ended configuration is listed for 1.7 mm and 2.5 mm wire sizes, providing two specified sizing options. The product is listed as a 4-piece set; confirm the exact contents, material, and compatibility with the supplier.

Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The Double Ended K-Wire Bender 1.7 mm and 2.5 mm is an orthopedic instrument intended to assist qualified surgical professionals with bending compatible Kirschner wires, commonly known as K-wires. These wires are used in selected orthopedic procedures for purposes such as temporary fixation, depending on the clinical application and the wire system.

The product title specifies two working sizes: 1.7 mm and 2.5 mm. Its double-ended design indicates that both ends are configured for different wire sizes, although the precise end geometry should be confirmed with the supplier. The listing also identifies a quantity of four pieces. It does not establish whether this means four individual benders or another combination of components, so an itemized packing list is recommended.

Double-Ended Design

A double-ended K-wire bender provides two working ends intended for different wire diameters. This configuration may offer flexibility when handling compatible wires of more than one size. The stated 1.7 mm and 2.5 mm sizing should be checked against the actual instrument markings and manufacturer specifications before use.

Correct size matching is important because an unsuitable bending surface may damage a wire or produce an unintended bend. Users should follow the wire and instrument manufacturers' instructions and avoid applying force beyond the intended operating limits.

Orthopedic Applications

K-wire benders may be used in selected orthopedic procedures where compatible Kirschner wires require controlled bending. The specific application depends on the surgical technique, wire placement, implant instructions, and the clinical requirements of the procedure.

This instrument should be used only by trained healthcare professionals familiar with the relevant wire system. The product title alone does not establish suitability for every K-wire type, wire material, or surgical application.

Material and Construction

The material composition and surface finish are not specified in the product title. Before purchasing, confirm whether the instrument is manufactured from surgical-grade stainless steel or another material, and request the applicable technical specifications.

The quality of the working ends, alignment, and overall construction can affect usability. Inspect the bender before use for visible damage, deformation, cracks, or wear. Do not use an instrument if its working ends are damaged or if its condition may compromise safe handling.

Set Quantity and Ordering Details

The listing specifies four pieces, but the exact contents are unclear. Confirm whether the set contains four benders, multiple size combinations, or additional components. Buyers should also verify the unit dimensions, wire-size compatibility, packaging, and supplier documentation before placing a bulk or institutional order.

For procurement purposes, requesting clear photographs of both ends and a written specification sheet can help verify that the instrument matches the required orthopedic wire sizes.

Cleaning, Sterilization, and Maintenance

Follow the manufacturer's instructions for cleaning, disinfection, sterilization, inspection, and storage. The product title does not specify whether the bender is reusable or which sterilization methods have been validated. Do not assume a particular sterilization cycle is appropriate without manufacturer guidance.

After use, inspect the working ends and overall instrument condition according to the facility's instrument-processing procedures. Remove damaged instruments from service and store processed instruments according to the manufacturer's recommendations.

Selecting the Correct K-Wire Bender

Before ordering, confirm the 1.7 mm and 2.5 mm working sizes, the exact double-ended design, the four-piece set composition, material, and compatibility with the intended K-wires. Ensure that the instrument is appropriate for the intended procedure and follow the instructions supplied with the wire and instrument systems.

Key Features

  • Double-ended orthopedic K-wire bender design

  • Listed for 1.7 mm and 2.5 mm wire sizes

  • Intended for bending compatible Kirschner wires

  • Two specified working sizes in one instrument design

  • For use in selected orthopedic procedures

  • Listed as a 4-piece set

  • Exact set composition requires confirmation

  • Material and surface finish not specified

  • Wire compatibility should be verified before use

  • Cleaning and sterilization must follow manufacturer instructions

Product Specifications

SpecificationDetails
Product NameDouble Ended K-Wire Bender
Instrument CategoryOrthopedic surgical instrument
Instrument FunctionBending compatible K-wires
DesignDouble ended
First Listed Wire Size1.7 mm
Second Listed Wire Size2.5 mm
Quantity4 pieces, as listed
MaterialNot specified
FinishNot specified
Overall DimensionsNot specified
Compatible Wire TypeConfirm with supplier/manufacturer
Reusable StatusConfirm with manufacturer
Sterilization MethodFollow manufacturer instructions
PackagingConfirm with supplier
ManufacturerNot specified
Country of OriginNot specified

FAQs

1. What is a double-ended K-wire bender used for?

It is an orthopedic instrument designed to assist with bending compatible Kirschner wires during selected surgical procedures.

2. Which wire sizes are specified for this bender?

The product title lists 1.7 mm and 2.5 mm wire sizes. Confirm the working-end dimensions with the supplier before use.

3. What does double ended mean?

It indicates that the instrument has two working ends. In this listing, the ends are associated with the two specified wire sizes, but the exact configuration should be verified.

4. What does the 4-piece quantity include?

The listing states four pieces, but the exact component breakdown is not provided. Request an itemized packing list from the supplier.

5. Can this bender be used with any K-wire?

No. Compatibility depends on wire diameter, material, design, and the instrument's specifications. Confirm compatibility with the manufacturer.

6. What material is the bender made from?

The material is not specified in the product title. Ask the supplier for the exact material and relevant technical documentation.

7. Is the K-wire bender reusable?

Reusable status is not specified. Check the manufacturer's labeling and instructions before cleaning, sterilizing, or reusing the instrument.

8. How should the instrument be sterilized?

Use the cleaning and sterilization process validated by the manufacturer. Do not assume that every sterilization method is suitable.

9. Who should use this orthopedic instrument?

It should be used by trained healthcare professionals familiar with the relevant K-wire system and the manufacturer's instructions.

10. What should be checked before purchasing?

Verify the 1.7 mm and 2.5 mm sizes, working-end configuration, material, four-piece set contents, wire compatibility, packaging, and applicable documentation.