
6 1/4″ Feder-Ossoff Microlaryn Scissors Sharp Angled Up Vertical
Direct Manufacturer Pricing • Tax Exclusive
- 6 1/4″ Feder-Ossoff Microlaryn Scissors Sharp Angled Up Vertical designed with an angled configuration for precise tissue cutting.
- Sharp angled up vertical blades provide a defined cutting profile for ENT procedures.
- Angled design supports a specialized working orientation within the operative field.
- Suitable for ENT and laryngeal surgery applications requiring an angled scissors.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 6 1/4″ Feder-Ossoff Microlaryn Scissors Sharp Angled Up Vertical is a specialized ENT instrument designed for fine cutting in delicate laryngeal procedures. Its sharp angled up vertical blades provide a distinct working orientation that can assist with positioning the cutting end within the operative field.
With an overall length of 6 1/4 inches and a precise cutting profile, this scissors provides a defined cutting profile for ENT applications. The angled design allows the working end to approach tissue from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 6 1/4-inch overall length for controlled manual handling.
- Sharp angled up vertical blades provide a defined cutting profile.
- Angled configuration for specialized working orientation.
- Designed for precise tissue excision with minimal trauma.
- Suitable for ENT and laryngeal surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Feder-Ossoff pattern for professional ENT instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Feder-Ossoff Microlaryn Scissors |
| Overall Length | 6 1/4″ |
| Working End / Blade / Jaw | Sharp angled up vertical blades |
| Configuration | Angled |
| Primary Function | Tissue Cutting |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | ENT / Laryngeal Surgery |
The 6 1/4″ Feder-Ossoff Microlaryn Scissors Sharp Angled Up Vertical combines a 6 1/4-inch overall length with sharp angled up vertical blades and angled configuration.
Its defined working profile is intended for precise tissue excision in ENT applications.
Design & Function
The Feder-Ossoff Microlaryn Scissors features an angled working configuration designed to provide a specialized orientation during laryngeal procedures. The sharp angled up vertical blade design can assist in positioning the cutting end according to the requirements of the operative field.
The sharp angled blade profile provides a defined cutting profile, while the 6 1/4-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring an angled scissors.
Surgical Applications
The 6 1/4″ Feder-Ossoff Microlaryn Scissors Sharp Angled Up Vertical may be used for ENT and laryngeal surgery applications involving precise tissue excision. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Feder-Ossoff Microlaryn Scissors before use, paying particular attention to the working end, blade alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Feder-Ossoff Microlaryn Scissors appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Scissors?
The overall length is 6 1/4 inches.
2. What is the working end / blade or tip design of the instrument?
It features sharp angled up vertical blades.
3. Is this Scissors curved or straight?
It features an angled configuration.
4. What is a Scissors used for?
It is designed for controlled tissue cutting in ENT applications.
5. What clinical advantage does the angled design provide?
The angled design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for ENT surgery?
It may be used in ENT and laryngeal surgery applications where an angled scissors is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Scissors be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
