
12″ Ferris-Smith IVD Rongeur 6x10mm Straight
Direct Manufacturer Pricing • Tax Exclusive
- 12″ Ferris-Smith IVD Rongeur 6x10mm Straight designed with a straight configuration for controlled removal of intervertebral disc material.
- 6 x 10 mm jaw dimension provides a defined grasping profile for neurosurgical procedures.
- Straight design supports a specialized working orientation within the operative field.
- Suitable for neurosurgical and spinal surgery applications requiring a straight rongeur.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 12″ Ferris-Smith IVD Rongeur 6x10mm Straight is a specialized neurosurgical instrument designed for controlled removal of larger volumes of intervertebral disc material. Its straight jaw with teeth provides a distinct working orientation that can assist with positioning the cutting end within the operative field.
With an overall length of 12 inches and a 6 x 10 mm jaw dimension, this rongeur provides a defined grasping profile for neurosurgical applications. The straight design allows the working end to approach the anatomical target from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 12-inch overall length for controlled manual handling.
- 6 x 10 mm jaw dimension provides a defined grasping profile.
- Straight configuration for specialized working orientation.
- Designed for controlled removal of intervertebral disc material.
- Suitable for neurosurgical applications.
- Supports positioning of the working end within the operative field.
- Specialized Ferris-Smith pattern for professional neurosurgical instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Ferris-Smith IVD Rongeur |
| Overall Length | 12″ |
| Working End / Blade / Jaw | 6 x 10 mm with Teeth |
| Configuration | Straight |
| Primary Function | Controlled Removal of Intervertebral Disc Material |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Neurosurgical |
The 12″ Ferris-Smith IVD Rongeur 6x10mm Straight combines a 12-inch overall length with a 6 x 10 mm jaw dimension and straight configuration.
Its defined working profile is intended for controlled removal of intervertebral disc material in neurosurgical applications.
Design & Function
The Ferris-Smith IVD Rongeur features a straight working configuration designed to provide a specialized orientation during spinal procedures. The straight jaw design can assist in positioning the working end according to the requirements of the operative field.
The 6 x 10 mm jaw dimension provides a defined grasping profile, while the 12-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for neurosurgical procedures requiring a straight rongeur.
Surgical Applications
The 12″ Ferris-Smith IVD Rongeur 6x10mm Straight may be used for neurosurgical and spinal surgery applications involving the controlled removal of intervertebral disc material. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the rongeur before use, paying particular attention to the working end, jaw alignment, and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the rongeur appropriately to protect its working end and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Rongeur?
The overall length is 12 inches.
2. What is the working end / blade or tip design of the instrument?
It features 6 x 10 mm with teeth.
3. Is this Rongeur curved or straight?
It features a Straight configuration.
4. What is a Rongeur used for?
It is designed for controlled removal of intervertebral disc material in neurosurgical applications.
5. What clinical advantage does the straight design provide?
The straight design provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for neurosurgery?
It may be used in neurosurgical and spinal surgery applications where a straight rongeur is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Rongeur be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
