Flieringa Scleral Fixation Rings – 23mm
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-65441
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
OtherSKU: SP-65441AISI 420 Martensitic

23mm Flieringa Scleral Fixation Ring

4.9 / 5.0•18 Verified OR Evaluations
$24.00$50.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $26.00 (52% OFF)
  • 23mm Flieringa Scleral Fixation Ring designed with a ring configuration for globe stabilization.
  • 23mm diameter provides a defined stabilization profile for ophthalmic procedures.
  • Durable design supports a specialized working orientation within the operative field.
  • Suitable for ophthalmic and intraocular applications requiring a fixation ring.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 23mm Flieringa Scleral Fixation Ring is a specialized ophthalmic instrument designed for stabilizing the globe during scleral fixation and complex intraocular procedures. Its 23mm diameter provides secure fixation for larger eyes, allowing surgeons to perform delicate microsurgical maneuvers with accuracy and control.

With an overall diameter of 23mm, this fixation ring provides a defined stabilization profile for ophthalmic applications. The durable construction ensures consistent performance even after repeated sterilization, supporting controlled manual manipulation during procedures.

Key Features

  • 23mm overall diameter for secure fixation in larger eyes.
  • Precision design provides a defined stabilization profile.
  • Durable construction for consistent performance.
  • Designed for ophthalmic procedures.
  • Supports positioning of the ring within the operative field.
  • Specialized Flieringa pattern for professional ophthalmic instrument sets.
  • Corrosion-resistant surgical-grade stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeFlieringa Scleral Fixation Ring
Overall Diameter23mm
ConfigurationRing
Primary FunctionGlobe Stabilization
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeOphthalmic Surgery

The 23mm Flieringa Scleral Fixation Ring combines a 23mm overall diameter with a precision design.
Its defined stabilization profile is intended for globe stabilization in ophthalmic applications.

Design & Function

The Flieringa Scleral Fixation Ring features a ring configuration designed to provide a specialized orientation during globe stabilization. The design can assist in positioning the ring according to the requirements of the operative field.

The 23mm diameter provides a defined stabilization profile, while the overall construction allows controlled manual positioning. Together, these dimensions provide a practical configuration for ophthalmic procedures requiring a fixation ring.

Surgical Applications

The 23mm Flieringa Scleral Fixation Ring may be used for ophthalmic and intraocular applications involving globe stabilization. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Flieringa Scleral Fixation Ring before use, paying particular attention to the ring's integrity and alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Flieringa Scleral Fixation Ring appropriately to protect its structure and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall diameter of this Flieringa Scleral Fixation Ring?
The overall diameter is 23mm.

2. What is the design of the instrument?
It features a ring configuration.

3. What is a Flieringa Scleral Fixation Ring used for?
It is designed for controlled globe stabilization in ophthalmic applications.

4. What clinical advantage does the design provide?
The design provides a specialized working orientation for positioning the ring within the operative field.

5. Is this instrument suitable for ophthalmic surgery?
It may be used in ophthalmic and intraocular applications where a 23mm fixation ring is appropriate.

6. Does the specification refer to the working end?
Yes. The supplied specification refers to the functional geometry of the instrument.

7. How should the Flieringa Scleral Fixation Ring be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.