Footplate Pick, angled 90° down, 6 3/8″
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-43956
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ENTSKU: SP-43956AISI 420 Martensitic

6 3/8″ Footplate Pick Angled 90° Down

4.9 / 5.0•18 Verified OR Evaluations
$85.00$101.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $16.00 (16% OFF)
  • 6 3/8″ Footplate Pick Angled 90° Down designed with a downward-angled configuration for precise manipulation of the stapes footplate.
  • 90° downward-angled tip provides a defined manipulation profile for ENT procedures.
  • Angled design supports a specialized working orientation within the operative field.
  • Suitable for ENT and middle ear surgery applications requiring a specialized Footplate Pick.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 6 3/8″ Footplate Pick Angled 90° Down is a specialized ENT instrument designed for precise manipulation of the stapes footplate and surrounding structures. Its 90° downward-angled tip provides a distinct working orientation that can assist with positioning the working end within the operative field.

With an overall length of 6 3/8 inches and a medium shaft, this Footplate Pick offers reach and stability, allowing surgeons to access the footplate with minimal tissue disruption. The downward angle provides excellent leverage for delicate movements, ideal for stapedectomy and middle ear procedures.

Key Features

  • 6 3/8-inch overall length for controlled manual handling.
  • 90° downward-angled tip provides a defined manipulation profile.
  • Medium shaft configuration for specialized working orientation.
  • Designed for precise manipulation of the stapes footplate.
  • Suitable for ENT and middle ear surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Footplate Pick pattern for professional ENT instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeFootplate Pick
Overall Length6 3/8″
Working End / Blade / Jaw90° downward-angled tip
ConfigurationAngled
Primary FunctionPrecise Manipulation
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeENT / Middle Ear Surgery

The 6 3/8″ Footplate Pick Angled 90° Down combines a 6 3/8-inch overall length with a 90° downward-angled tip. Its defined working profile is intended for precise manipulation in ENT applications.

Design & Function

The Footplate Pick features a 90° downward-angled configuration designed to provide a specialized orientation during stapedectomy procedures. The angled tip can assist in positioning the working end according to the requirements of the operative field.

The 90° downward-angled tip provides a defined manipulation profile, while the 6 3/8-inch overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a specialized instrument.

Surgical Applications

The 6 3/8″ Footplate Pick Angled 90° Down may be used for ENT and middle ear surgery applications involving precise manipulation of the stapes footplate. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Footplate Pick before use, paying particular attention to the working end and tip alignment. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Footplate Pick appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Footplate Pick?
The overall length is 6 3/8 inches.

2. What is the working end / blade or tip design of the instrument?
It features 90° downward-angled tip.

3. Is this Footplate Pick curved or straight?
It features an angled configuration.

4. What is a Footplate Pick used for?
It is designed for controlled precise manipulation in ENT applications.

5. What clinical advantage does the angled design provide?
The angled design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for ENT surgery?
It may be used in ENT and middle ear surgery applications where a 90° angled Footplate Pick is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Footplate Pick be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.