Gass Corneoscleral Punch 1mm diameter tip
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-65480
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
OtherSKU: SP-65480AISI 420 Martensitic

1mm Gass Corneoscleral Punch Tip

4.9 / 5.0•18 Verified OR Evaluations
$460.00$487.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $27.00 (6% OFF)
  • 1mm Gass Corneoscleral Punch Tip designed with a compact configuration for controlled tissue cutting and shaping.
  • 1 mm diameter tip provides a defined cutting profile for ophthalmic procedures.
  • Compact design supports a specialized working orientation within the operative field.
  • Suitable for ophthalmic and anterior segment surgery applications requiring a compact instrument type.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 1mm Gass Corneoscleral Punch Tip is a specialized ophthalmic instrument designed for creating controlled openings in corneal or scleral tissue during glaucoma and anterior segment procedures. Its sharp circular punch tip provides a distinct working orientation that can assist with positioning the cutting end within the operative field.

With an overall length of and a 1 mm diameter tip, this punch provides a defined cutting profile for ophthalmic applications. The compact design allows the working end to approach the tissue from a specialized angle, supporting controlled manual manipulation during procedures.

Key Features

  • for controlled manual handling.
  • 1 mm diameter tip provides a defined cutting profile.
  • Compact configuration for specialized working orientation.
  • Designed for controlled tissue cutting and shaping.
  • Suitable for ophthalmic and anterior segment surgery applications.
  • Supports positioning of the working end within the operative field.
  • Specialized Gass pattern for professional ophthalmic instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeGass Corneoscleral Punch
Overall Length
Working End / Blade / Jaw1 mm diameter tip
ConfigurationCompact
Primary FunctionTissue Cutting and Shaping
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeOphthalmic / Anterior Segment Surgery

The 1mm Gass Corneoscleral Punch Tip combines a overall length with a 1 mm diameter tip and compact configuration.
Its defined working profile is intended for controlled tissue cutting and shaping in ophthalmic applications.

Design & Function

The Gass Corneoscleral Punch features a compact working configuration designed to provide a specialized orientation during tissue preparation. The sharp circular punch tip can assist in positioning the working end according to the requirements of the operative field.

The 1 mm diameter tip provides a defined cutting profile, while the overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ophthalmic procedures requiring a compact instrument type.

Surgical Applications

The 1mm Gass Corneoscleral Punch Tip may be used for ophthalmic and anterior segment surgery applications involving precise tissue cutting. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the Gass Corneoscleral Punch before use, paying particular attention to the working end and cutting edges. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Gass Corneoscleral Punch appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Gass Corneoscleral Punch?
The overall length is .

2. What is the working end / blade or tip design of the instrument?
It features 1 mm diameter tip.

3. Is this Gass Corneoscleral Punch curved or straight?
It features a compact configuration.

4. What is a Gass Corneoscleral Punch used for?
It is designed for controlled tissue cutting and shaping in ophthalmic applications.

5. What clinical advantage does the compact design provide?
The compact design provides a specialized working orientation for positioning the working end within the operative field.

6. Is this instrument suitable for ophthalmic surgery?
It may be used in ophthalmic and anterior segment applications where a compact Gass Corneoscleral Punch is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Gass Corneoscleral Punch be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.