Guilford Wright Suction Tube 20g
Hover to inspect tip
100% Autoclavable & Passivated AISI 420 SteelSKU: SP-45366
OR & Quality SpecificationsHospital Grade
Steel MetallurgyGerman AISI 420 Martensitic
Sterilization Cycle134°C / 273°F Steam Autoclave
Quality StandardISO 13485:2016 & CE Mark
Optical FinishAnti-Glare Satin Matte
Electrochemical PassivationCSSD Laser Batch Tracking
ENTSKU: SP-45366AISI 420 Martensitic

20G Guilford Wright Suction Tube Atraumatic Tip

4.9 / 5.0•18 Verified OR Evaluations
$60.00$100.00/ unit

Direct Manufacturer Pricing • Tax Exclusive

SAVE $40.00 (40% OFF)
  • 20G Guilford Wright Suction Tube designed with an atraumatic configuration for controlled fluid aspiration.
  • 20G diameter provides a defined suction profile for ENT procedures.
  • Atraumatic design supports a specialized working orientation within the operative field.
  • Suitable for ENT and microsurgery applications requiring a precise suction instrument.
Door-to-Door DDP Delivery
Duties & Taxes Paid

All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.

🎁 Free delivery over $1,000+ USDShipping Policy →

Hospital & Volume Procurement Pricing

Auto-applied at checkout
Door-to-Door DDP Delivery: Duties & taxes pre-paid for USA, UK, Canada, Europe & AUS (Free on $1,000+)
Lifetime Warranty: Guaranteed metallurgy and craftsmanship integrity
OR Sterilization Certified: Medical Grade AISI 420 Passivated German Steel

The 20G Guilford Wright Suction Tube is a specialized ENT instrument designed for controlled fluid aspiration in delicate surgical procedures. Its 20-gauge diameter allows precise suction in small or sensitive anatomical areas, making it ideal for operations where tissue protection is critical.

With an overall length of and a smooth internal lumen, this suction tube provides uninterrupted fluid removal. The atraumatic tip minimizes trauma to surrounding tissues, supporting effective and safe surgical practices.

Key Features

  • for precise handling in delicate areas.
  • 20G diameter provides a defined suction profile.
  • Atraumatic tip configuration for minimizing tissue trauma.
  • Designed for controlled fluid aspiration in ENT and microsurgical procedures.
  • Suitable for delicate operations requiring precision and care.
  • Supports effective fluid removal within the operative field.
  • Specialized Guilford Wright pattern for professional ENT instrument sets.
  • Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
  • Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).

Technical Specifications

SpecificationDetails
Instrument TypeGuilford Wright Suction Tube
Overall Length
Working End / Blade / Jaw20G diameter
ConfigurationAtraumatic Tip
Primary FunctionFluid Aspiration
MaterialGerman Stainless Steel (AISI 420)
SterilizationSteam Autoclavable (up to 134°C / 273°F)
Application TypeENT / Microsurgery

The 20G Guilford Wright Suction Tube combines a overall length with a 20G diameter and atraumatic tip configuration.
Its defined working profile is intended for controlled fluid aspiration in ENT and microsurgical applications.

Design & Function

The Guilford Wright Suction Tube features an atraumatic tip designed to provide a specialized orientation during fluid aspiration. The smooth internal lumen can assist in positioning the suction tube according to the requirements of the operative field.

The 20G diameter provides a defined suction profile, while the allows controlled manual positioning. Together, these dimensions provide a practical configuration for ENT procedures requiring a precise suction instrument.

Surgical Applications

The 20G Guilford Wright Suction Tube may be used for ENT and microsurgery applications involving controlled fluid aspiration. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.

Handling & Instrument Care

Inspect the suction tube before use, paying particular attention to the working end and tip integrity. Ensure the instrument is properly aligned and free from visible damage or wear before use.

After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the suction tube appropriately to protect its working end and prevent unnecessary contact with other instruments.

Frequently Asked Questions

1. What is the overall length of this Suction Tube?
The overall length is .

2. What is the working end / blade or tip design of the instrument?
It features 20G diameter.

3. Is this Suction Tube curved or straight?
It features a Atraumatic Tip configuration.

4. What is a Suction Tube used for?
It is designed for controlled fluid aspiration in ENT applications.

5. What clinical advantage does the atraumatic tip provide?
The atraumatic tip provides a specialized working orientation for minimizing trauma to surrounding tissues.

6. Is this instrument suitable for ENT surgery?
It may be used in ENT and microsurgery applications where a 20G suction tube is appropriate.

7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.

8. How should the Suction Tube be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.