Herbert Cannulated 3.0mm Screw Set, 51 Pieces
Direct Manufacturer Pricing • Tax Exclusive
The Herbert Cannulated 3.0mm Screws Set with Driver, 51 Pcs, is an orthopedic fixation system designed for compatible small bone procedures. The set combines 3.0mm cannulated screws with a corresponding driver to support accurate screw placement under appropriate surgical guidance. Confirm the included screw sizes, quantities, and compatibility with the manufacturer before ordering.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The Herbert Cannulated 3.0mm Screws Set with Driver, 51 Pcs, is an orthopedic instrument and implant set intended for procedures requiring compatible cannulated screw fixation. Herbert-type screws are commonly associated with headless compression designs that can provide compression across selected fracture sites or bone fragments. However, the exact screw geometry, compression mechanism, and intended indications for this particular set must be confirmed through the manufacturer's specifications.
Cannulated Screw Design
Cannulated screws feature a hollow central channel that allows placement over a compatible guide wire. This design can help surgeons establish the intended trajectory before advancing the screw into the prepared bone. Guide-wire placement and screw insertion must follow the surgical technique specified for the particular implant system.
The 3.0mm nominal screw diameter identifies the stated size of the screws in this set. The actual thread configuration, core diameter, available lengths, and headless or headed design should be verified with the supplier. These details are important when matching implants to fracture patterns, bone dimensions, and the requirements of the planned procedure.
Herbert-Type Screw Applications
Herbert-type compression screws may be used in selected orthopedic procedures involving small bones and bone fragments. Depending on the specific implant design and its approved indications, these procedures may include fixation of selected fractures or osteotomies in areas such as the wrist, hand, or foot.
Not every 3.0mm cannulated screw is appropriate for every anatomical site or fracture pattern. The operating surgeon must determine implant suitability based on patient anatomy, fracture characteristics, bone quality, imaging findings, and the manufacturer's instructions for use.
Driver and Instrument Compatibility
The set includes a driver intended to support insertion of compatible screws. Correct driver engagement is essential for controlled insertion and to reduce the risk of damaging the screw's drive interface. The driver type, tip configuration, and compatibility with the screw system should be verified before use.
Cannulated screw insertion generally involves guide-wire placement, appropriate preparation where required, and advancement of the screw along the established trajectory. The precise steps vary by implant design. Surgeons should follow the manufacturer's surgical technique and use only compatible guide wires, drills, measuring instruments, and drivers.
Set Configuration and Organization
The product title identifies a 51-piece set containing Herbert cannulated 3.0mm screws and a driver. The exact distribution of screw lengths, number of each size, and additional accessories are not specified in the title. Buyers should request a complete inventory list before purchasing to ensure that the set contains the sizes and components required for the intended procedures.
An organized screw set can help clinical teams identify the appropriate implant size and manage instruments during orthopedic procedures. Clear size markings and a suitable storage arrangement, if included, can also support inventory control. These features should be confirmed against the actual product supplied.
Materials and Implant Quality
The screw material is not specified by the product title. Orthopedic fixation screws may be manufactured from implant-grade stainless steel or titanium alloys, depending on the implant system. Material selection affects mechanical properties, imaging characteristics, and compatibility with other implants.
Buyers should verify the precise alloy, implant classification, applicable biocompatibility documentation, and regulatory status. Implant materials and dimensions should not be assumed from the product name alone. The screws must be used only in accordance with the manufacturer's labeling and applicable clinical requirements.
Sterilization, Handling, and Storage
Confirm whether the screws are supplied sterile or non-sterile and whether they are intended for single use. Implant screws must be handled according to their labeling and the manufacturer's instructions. Do not reprocess or reuse single-use implants unless the manufacturer and applicable regulations explicitly permit it.
Reusable instruments, including the driver, must be cleaned, inspected, and sterilized according to validated instructions. Inspect the driver for wear or damage and check screw packaging for integrity, expiration information where applicable, and signs of contamination before use.
Professional Orthopedic Procurement
The Herbert Cannulated 3.0mm Screws Set with Driver, 51 Pcs, is intended for professional orthopedic implant procurement. Before ordering, confirm the screw lengths and quantities, head and thread design, driver compatibility, material, sterility status, and intended indications. Matching these specifications to the manufacturer's documentation helps ensure that the set is appropriate for the planned fixation procedure.
Key Features
Herbert-type cannulated orthopedic screw set
Stated nominal screw diameter of 3.0mm
51-piece set configuration
Includes a compatible driver, subject to model verification
Cannulated design supports guide-wire-assisted placement
Intended for selected small bone fixation applications
Screw lengths and quantities require confirmation
Thread and compression design depend on the specific model
Implant material and regulatory documentation should be verified
Sterility status must be confirmed before use
Intended for use by qualified orthopedic professionals
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Herbert Cannulated Screw Set |
| Screw Diameter | 3.0mm nominal |
| Set Size | 51 pieces |
| Included Instrument | Driver |
| Implant Type | Cannulated orthopedic fixation screws |
| Screw Design | Herbert-type; exact design to be confirmed |
| Cannulation | Central guide-wire channel |
| Typical Application | Selected small bone fixation procedures |
| Screw Lengths | Confirm with manufacturer |
| Screw Quantity by Size | Confirm with manufacturer |
| Material | Confirm implant-grade alloy with manufacturer |
| Sterility Status | Confirm product labeling |
| Reusability | Implants and instruments subject to their respective labeling |
| Intended Users | Qualified orthopedic surgical professionals |
Frequently Asked Questions
1. What is a Herbert cannulated 3.0mm screw used for?
Herbert-type cannulated screws are used for selected orthopedic fixation procedures involving bone fragments or fractures. The exact indications depend on the screw design, anatomical site, and manufacturer's instructions.
2. What does cannulated mean in orthopedic screws?
Cannulated screws contain a hollow central channel that allows them to be advanced over a compatible guide wire. This supports planned screw trajectory and positioning during appropriate procedures.
3. What is included in the 51-piece Herbert screw set?
The product title specifies a 51-piece set with a driver. The exact number of screws, available lengths, and any additional accessories should be confirmed with the supplier.
4. What is the diameter of these Herbert screws?
The stated nominal diameter is 3.0mm. Buyers should confirm the available lengths, thread dimensions, and other implant measurements in the manufacturer's specifications.
5. Does the Herbert cannulated screw set include a driver?
Yes, the product title states that a driver is included. Confirm the driver's tip configuration and compatibility with the supplied screws before purchase.
6. Are Herbert cannulated screws made from titanium or stainless steel?
The material for this specific set is not established by the title. Ask the manufacturer to confirm the exact implant-grade alloy and its supporting documentation.
7. Are the screws supplied sterile?
Sterility status must be verified from the packaging and manufacturer's documentation. Use implants only according to their labeling and applicable sterile handling requirements.
8. What should buyers verify before purchasing this orthopedic screw set?
Confirm the screw lengths and quantities, implant design, material, driver compatibility, sterility status, regulatory documentation, and approved indications to ensure suitability for the intended procedure.