Hill Ferguson Rectal Retractor Fiber Optic 35mm X 70mm Blade Size Total...
Direct Manufacturer Pricing • Tax Exclusive
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The Hill Ferguson Rectal Retractor is a specialized surgical instrument designed to assist with controlled tissue retraction and exposure during rectal, anorectal, and colorectal procedures. Its 35 × 70 mm blade provides a defined retraction surface for maintaining access to the operative area while the integrated fiber optic illumination helps improve visualization.
Fiber optic illumination is particularly useful in surgical fields where shadows or limited access can make visualization more challenging. By directing light closer to the operative site, the integrated optical system can provide focused illumination without relying solely on external operating-room lighting. The instrument should be connected only to a compatible fiber optic light source, and the optical components should be inspected before use.
The 35 × 70 mm blade specification provides a clear reference for the working portion of the retractor. Its size is designed to support controlled exposure while allowing the surgeon to select an appropriate instrument according to patient anatomy and procedural requirements. The exact working depth, overall length, blade curvature, and handle configuration should be confirmed from the manufacturer's specifications if required.
The Hill Ferguson design is intended for professional surgical use and can be incorporated into colorectal, anorectal, and general surgical instrument sets. It may assist with procedures where controlled retraction of tissue is necessary to maintain an accessible and visible operative field.
Proper cleaning and maintenance are important for preserving both the mechanical function of the retractor and the performance of its fiber optic system. After use, the instrument should be cleaned according to the manufacturer's instructions and thoroughly inspected for damage, contamination, or abnormalities. Fiber optic surfaces and connection points should receive particular care to prevent scratching or damage.
If supplied as a reusable surgical instrument, the retractor should be processed according to the manufacturer's validated instructions and the healthcare facility's sterilization protocol. Before each procedure, verify that the blade is intact and that the fiber optic illumination system provides appropriate light output.
The product information supplied specifies a 35 × 70 mm blade size. Other specifications, including total overall length, material, fiber optic connector type, and sterilization compatibility, should be confirmed against the manufacturer's documentation.
Key Features
- Hill Ferguson rectal retractor design
- Integrated fiber optic illumination
- 35 × 70 mm blade size
- Designed for rectal and anorectal procedures
- Supports controlled tissue retraction
- Provides focused illumination near the operative field
- Helps maintain surgical exposure and visualization
- Suitable for colorectal and general surgical settings
- Fiber optic system requires compatible light source
- Designed for professional surgical use
- Reusable status depends on the specific configuration
- Requires appropriate cleaning and sterilization procedures
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Hill Ferguson Rectal Retractor |
| Instrument Type | Rectal / Anorectal Retractor |
| Blade Size | 35 × 70 mm |
| Illumination | Fiber Optic |
| Primary Application | Rectal, Anorectal & Colorectal Surgery |
| Function | Tissue Retraction and Surgical Exposure |
| Overall Length | Not specified |
| Blade Material | Not specified |
| Handle Material | Not specified |
| Fiber Optic Connector | Not specified |
| Reusable | Not specified |
| Sterilization | Follow manufacturer and facility-validated protocols |
FAQs
1. What is a Hill Ferguson Rectal Retractor?
The Hill Ferguson Rectal Retractor is a specialized surgical retractor designed to provide controlled tissue retraction and exposure during appropriate rectal, anorectal, and colorectal procedures.
2. What is the blade size?
The specified blade size is 35 × 70 mm.
3. What is the purpose of the fiber optic illumination?
The fiber optic system provides focused illumination close to the operative field, helping improve visualization during procedures where additional localized lighting is beneficial.
4. What procedures can this retractor support?
It is designed for appropriate rectal and anorectal surgical procedures where controlled tissue retraction and operative exposure are required. The surgeon determines its suitability for a particular procedure.
5. Does it require a fiber optic light source?
Yes. The fiber optic illumination system requires a compatible light source and connector. The exact connector specification should be confirmed before ordering.
6. Is the Hill Ferguson retractor reusable?
The supplied product information does not specify reusability. If supplied as a reusable instrument, it should be cleaned, inspected, and sterilized according to the manufacturer's instructions.
7. What is the total length of the retractor?
The product title provides the blade size but does not specify the total overall length. This measurement should be confirmed from the manufacturer's product documentation.
8. How should the fiber optic components be maintained?
Fiber optic surfaces and connectors should be handled carefully, cleaned according to manufacturer instructions, and inspected regularly for damage or reduced light transmission.