
9mm Hoffer Optic Zone Marker
Direct Manufacturer Pricing • Tax Exclusive
- 9mm Hoffer Optic Zone Marker designed with a straight configuration for precise optical zone marking.
- Precision marking edge provides a defined marking profile for ophthalmic procedures.
- Straight design supports a specialized working orientation within the operative field.
- Suitable for ophthalmic and refractive surgery applications requiring a straight optic zone marker.
All import duties, tariffs & taxes are 100% pre-paid for USA, UK, Canada, EUROPE & Australia (AUS). Zero surprise customs bills at delivery.
Hospital & Volume Procurement Pricing
The 9mm Hoffer Optic Zone Marker is a specialized ophthalmic instrument designed for marking the optical zone on the cornea during refractive and anterior segment procedures. Its larger 9mm diameter allows surgeons to define a wider optical zone, assisting in accurate surgical planning and alignment. The precision marking edge produces uniform and clearly visible marks without damaging delicate corneal tissue.
With an overall length of 9mm and a precision marking edge, this optic zone marker provides a defined marking profile for ophthalmic applications. The ergonomic design allows the working end to approach the cornea from a specialized angle, supporting controlled manual manipulation during procedures.
Key Features
- 9mm overall length for precise optical zone marking.
- Precision marking edge provides a defined marking profile.
- Ergonomic design for specialized working orientation.
- Designed for accurate surgical planning and alignment.
- Suitable for ophthalmic and refractive surgery applications.
- Supports positioning of the working end within the operative field.
- Specialized Hoffer pattern for professional ophthalmic instrument sets.
- Corrosion-resistant surgical-grade German AISI 420 stainless steel construction.
- Autoclavable and reusable (Steam autoclave up to 134°C / 273°F).
Technical Specifications
| Specification | Details |
|---|---|
| Instrument Type | Hoffer Optic Zone Marker |
| Overall Length | 9mm |
| Working End / Blade / Jaw | Precision marking edge |
| Configuration | Straight |
| Primary Function | Optical Zone Marking |
| Material | German Stainless Steel (AISI 420) |
| Sterilization | Steam Autoclavable (up to 134°C / 273°F) |
| Application Type | Ophthalmic / Refractive Surgery |
The 9mm Hoffer Optic Zone Marker combines a 9mm overall length with a precision marking edge and straight configuration.
Its defined marking profile is intended for accurate surgical planning in ophthalmic applications.
Design & Function
The Hoffer Optic Zone Marker features a straight working configuration designed to provide a specialized orientation during corneal marking. The precision marking edge can assist in positioning the working end according to the requirements of the operative field.
The precision marking edge provides a defined marking profile, while the 9mm overall length allows controlled manual positioning. Together, these dimensions provide a practical configuration for ophthalmic procedures requiring a straight optic zone marker.
Surgical Applications
The 9mm Hoffer Optic Zone Marker may be used for ophthalmic and refractive surgery applications involving precise optical zone marking. Specific use depends on the surgical procedure, technique, anatomical site, and preference of the clinical team.
Handling & Instrument Care
Inspect the Hoffer Optic Zone Marker before use, paying particular attention to the marking edge and overall integrity. Ensure the instrument is properly aligned and free from visible damage or wear before use.
After use, clean and process the instrument according to the manufacturer's validated instructions and the healthcare facility's established instrument-processing protocols. Store the Hoffer Optic Zone Marker appropriately to protect its marking edge and prevent unnecessary contact with other instruments.
Frequently Asked Questions
1. What is the overall length of this Hoffer Optic Zone Marker?
The overall length is 9mm.
2. What is the working end / blade or tip design of the instrument?
It features precision marking edge.
3. Is this Hoffer Optic Zone Marker curved or straight?
It features a Straight configuration.
4. What is a Hoffer Optic Zone Marker used for?
It is designed for controlled optical zone marking in ophthalmic applications.
5. What clinical advantage does the precision marking edge provide?
The marking edge provides a specialized working orientation for positioning the working end within the operative field.
6. Is this instrument suitable for ophthalmic surgery?
It may be used in ophthalmic and refractive surgery applications where a straight optic zone marker is appropriate.
7. Does the specification refer to the working end?
Yes. The supplied specification refers to the working profile and functional geometry of the instrument.
8. How should the Hoffer Optic Zone Marker be cleaned and maintained?
It should be inspected, cleaned, steam autoclaved (up to 134°C / 273°F), and stored according to manufacturer instructions and healthcare facility protocols.
